Development of Blood Pressure Simulator for Test of the Arm-type Automatic Blood Pressure Monitor

Abstract: Blood pressure is possible to diagnose a disease associated with blood pressure and judgment the current health of patients. Automatic blood pressure monitor capable of measuring a blood pressure easily in hospital and at home have become spread. In this study, we developed the blood pressure simulator (BPS) that can test the arm-type automatic blood pressure monitor that is commonly used in hospital. BPS is to produce a pressure similar to the pressure wave generated in the human blood using a servo disk moto… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
5
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 6 publications
0
5
0
Order By: Relevance
“…In addition, water supply and water discharge are necessary before and after the inspection; therefore, it is not suitable for quick and convenient on-site inspections. In addition, Kim et al proposed an arm-type BP simulator that utilizes pneumatic pressure, not hydraulic pressure [8]. However, they used a bellows, servo disk motor, and screw piston for pneumatic pressure generation; therefore, it is difficult to manufacture a small and light single-pieced device, and as a result, it is not suitable for on-site inspections, too.…”
Section: Discussionmentioning
confidence: 99%
“…In addition, water supply and water discharge are necessary before and after the inspection; therefore, it is not suitable for quick and convenient on-site inspections. In addition, Kim et al proposed an arm-type BP simulator that utilizes pneumatic pressure, not hydraulic pressure [8]. However, they used a bellows, servo disk motor, and screw piston for pneumatic pressure generation; therefore, it is difficult to manufacture a small and light single-pieced device, and as a result, it is not suitable for on-site inspections, too.…”
Section: Discussionmentioning
confidence: 99%
“…For the blood vessel, the inner and outer radii were set to 2.25 and 2.75 mm, respectively, and the Poisson's ratio and elastic modulus were set to 0.45 and 450 kPa, respectively 23,30 . For the soft tissue, the inner and outer radii were set to 2.75 mm and 45 mm, respectively, and the Poisson's ratio and elastic modulus were set to 0.45 and 47.5 kPa, respectively 34 .…”
Section: Methodsmentioning
confidence: 99%
“…The soft tissue was assumed to be composed of linear elastic materials; as the strain was less than 10% during the blood pressure measurement and within the range it exhibits linear elastic behavior 23 . The soft tissue was modeled with an elastic modulus of 47.5 kPa and a Poisson's ratio of 0.45 34 and the artery wall was modeled with an elastic modulus of 450 kPa and a Poisson's ratio of 0.45 23,30 . Here, the radius, elasticity, and thickness of the artery and the elasticity of the soft tissue were varied for the parametric study.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations