2023
DOI: 10.1177/14680874231200759
|View full text |Cite
|
Sign up to set email alerts
|

Development of correlation model for cavitating spray using Eulerian simulations

Xinlei Liu,
Junjun Guo,
Hong G. Im

Abstract: Modern high-pressure injection systems for heavy-duty applications are prone to cavitation, which may have a detrimental effect on the system integrity. The present study aims to develop reliable correlations for Lagrangian engineering simulations to predict the onset of cavitation. Using the extensive data generated from the high-fidelity Eulerian volume-of-fluid (VOF) simulations of a single-hole injector for a wide range of operating conditions, a proper set of discharge ( Cd) and contraction ( Ca) coeffici… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 50 publications
0
1
0
Order By: Relevance
“…At approximately 0-0.15 ms in the initial stage of spray process, the gas STP under flare flash boiling conditions were lower than that under cold conditions, although the ambient density under flare flash boiling conditions was lower than those under the non-flash boiling conditions. This is because, at P amb of 0.2 MPa, liquid ammonia which is filled with the spray hole generates intensive cavitation at the time when injector needle started lifting [21][22][23], this behavior will block the nozzle and cause a different tendency with a shorter penetration than the other cold conditions in the initial stage. Additionally, similar results were also found in the research of Ainsalo [24], although he investigated high-pressure propane sprays using a diesel injector.…”
Section: Effect Of Ambient Pressure On Spray Under 80 Mpa Injection P...mentioning
confidence: 99%
“…At approximately 0-0.15 ms in the initial stage of spray process, the gas STP under flare flash boiling conditions were lower than that under cold conditions, although the ambient density under flare flash boiling conditions was lower than those under the non-flash boiling conditions. This is because, at P amb of 0.2 MPa, liquid ammonia which is filled with the spray hole generates intensive cavitation at the time when injector needle started lifting [21][22][23], this behavior will block the nozzle and cause a different tendency with a shorter penetration than the other cold conditions in the initial stage. Additionally, similar results were also found in the research of Ainsalo [24], although he investigated high-pressure propane sprays using a diesel injector.…”
Section: Effect Of Ambient Pressure On Spray Under 80 Mpa Injection P...mentioning
confidence: 99%