2009
DOI: 10.1016/j.enconman.2008.11.003
|View full text |Cite
|
Sign up to set email alerts
|

Development of electrical efficiency measurement techniques for 10kW-class SOFC system: Part II. Uncertainty estimation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2009
2009
2020
2020

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 8 publications
(10 citation statements)
references
References 9 publications
0
10
0
Order By: Relevance
“…As shown in TABLE II, linearity of MFC readings was ±0.4-1.5% at 40-100% of full scale (F.S.%), while repeatability was ±0.13-0.33% at 40-100 F.S.%. Each uncertainty was combined according to the law of uncertainty propagation (2). Therefore, relative uncertainty of MFC readings at 40-100 F.S.% was found to be ±0.62%, ±1.55%, and ±0.46% for H 2 , O 2 , and CO 2 , respectively.…”
Section: Uncertainty Analysis For Generated Model-reformate-gasesmentioning
confidence: 99%
See 2 more Smart Citations
“…As shown in TABLE II, linearity of MFC readings was ±0.4-1.5% at 40-100% of full scale (F.S.%), while repeatability was ±0.13-0.33% at 40-100 F.S.%. Each uncertainty was combined according to the law of uncertainty propagation (2). Therefore, relative uncertainty of MFC readings at 40-100 F.S.% was found to be ±0.62%, ±1.55%, and ±0.46% for H 2 , O 2 , and CO 2 , respectively.…”
Section: Uncertainty Analysis For Generated Model-reformate-gasesmentioning
confidence: 99%
“…2. At a temperature T 0 , uncertainty of gas compositions due to uncertainty of temperature-measurement, u(T 0 ) will be expressed as f ' (T 0 ) u(T 0 ) where u(T 0 ) = ±7.0ºC (2). As summarized in TABLE IV, the uncertainties of H 2 , H 2 O, and CH 4 compositions are higher at lower temperatures.…”
Section: Uncertainty Analysis For Generated Model-reformate-gasesmentioning
confidence: 99%
See 1 more Smart Citation
“…As part of the JIS TS work and a 2007 project on efficiency measurements using an actual 10-kW SOFC system, we conducted uncertainty analyses of measured input and output values and included uncertainty data in our evaluation of the measured efficiency. [6] This paper describes the three-year project commissioned by METI in 2007 to develop an international standard for the cell/stack performance testing of SOFC, and our group's work on uncertainty evaluation as part of this project.…”
Section: Evaluating Uncertainty For the Standardization Of Single Celmentioning
confidence: 99%
“…We have developed techniques to estimate electric efficiency of SOFC systems fueled by LNG-based town-gas as reasonably as η e can be distinguished by 1 point; e.g. to tell η e = 50% from 51% under a New Energy and Industrial Technology Development Organization (NEDO) project in Japan (7,8). Since thermal mass-flow meters (MFM) or controllers (MFC) have been widely used in research and developments of fuel cells and also in testing stacks and systems, how to deal with MFM and MFC for natural gas has been investigated in the project.…”
Section: Introductionmentioning
confidence: 99%