2017
DOI: 10.1016/j.chemosphere.2017.02.060
|View full text |Cite
|
Sign up to set email alerts
|

Development of electrochemical biosensor for detection of pathogenic microorganism in Asian dust events

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
19
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 42 publications
(19 citation statements)
references
References 31 publications
0
19
0
Order By: Relevance
“…c) Electrochemical impedance spectroscopy (EIS) in 100 mM LiClO 4 solution in the form of a Nyquist plot and corresponding equivalent circuit model associated with biorecognition element immobilization and detection of S. typhimurium (Sheikhzadeh et al 2016). d) Conductometry data for varying concentrations of B. subtilis (Yoo et al 2017). (Randles, 1947).…”
Section: Electrochemical Impedance Spectroscopymentioning
confidence: 99%
See 1 more Smart Citation
“…c) Electrochemical impedance spectroscopy (EIS) in 100 mM LiClO 4 solution in the form of a Nyquist plot and corresponding equivalent circuit model associated with biorecognition element immobilization and detection of S. typhimurium (Sheikhzadeh et al 2016). d) Conductometry data for varying concentrations of B. subtilis (Yoo et al 2017). (Randles, 1947).…”
Section: Electrochemical Impedance Spectroscopymentioning
confidence: 99%
“…As shown in Fig. 5d, Yoo et al used a conductometric biosensor with CNT-based electrodes for the detection of B. subtilis (Yoo et al 2017). Mannoor et al used a previously described conductometric biosensor to detect S. aureus and Helicobacter pylori on tooth enamel (Mannoor et al 2012).…”
Section: Conductometrymentioning
confidence: 99%
“…An excellent limit of detection (8 CFU mL −1 ) was obtained, which could be attributed to the enhanced photo-electrochemical electron transfer, photoluminescence of graphene quantum dots, and specific binding between the bacteria and polyclonal antibodies [ 46 ]. Also in airborne dust, specifically during Asian dust events, the detection of pathogenic bacteria ( B. subtilis ) was reported through an electrochemical immunosensor based on SWCNT-gold electrodes [ 47 ]. A limit of detection of 10 2 CFU mL −1 was obtained in a detection range between 10 2 and 10 10 CFU mL −1 while the response time was 10 min.…”
Section: Biosensors For Environmental Monitoringmentioning
confidence: 99%
“…A comprehensive database of DSM, environmental metadata, and implementation of disease surveillance strategies in downwind environments are all prerequisites for establishing a clear link between DSM and human health concerns. Surveillance strategies based on emerging biosensor technologies with high sensitivity and specificity for detection of windborne pathogens could provide advanced warning system for at-risk populations ( Yoo et al. 2017 ).…”
Section: Potential Ramifications Of Dsm On Human and Ecosystem Healthmentioning
confidence: 99%
“…2017a ) Fusarium ; Cladosporium ; Ulocladium ; Aspergillus ; Alternaria Arabian dust Saudi Arabia Fungal culture Human ( Vijayakumar et al. 2017 ) Bacillus subtilis Asian dust Carbon nanotubes (SWCNTs)-based electrochemical biosensor Human ( Yoo et al. 2017 ) -Bacterial Quantity -Bacterial communities Asian dust Beijing, China High throughput Metagenomics: -16S rRNA gene sequencing Bacterial abundance: qPCR N/D ( Zhen et al.…”
Section: Perspectivesmentioning
confidence: 99%