2020
DOI: 10.1080/03639045.2020.1791168
|View full text |Cite
|
Sign up to set email alerts
|

Development of food grade 3D printable ink based on pectin containing cannabidiol/cyclodextrin inclusion complexes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
14
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 26 publications
(18 citation statements)
references
References 61 publications
4
14
0
Order By: Relevance
“…12 , Fig. 13 ) presented an endothermic peak that indicates the melting point of 68.97 °C confirming the results of Andriotis and his co-authors (69 °C) ( Andriotis et al, 2020 ). The T onset was 66.45 °C, the T endset was 71.43 °C while the ΔH = 20.12 J/g.…”
Section: Compatibility Studiessupporting
confidence: 84%
See 2 more Smart Citations
“…12 , Fig. 13 ) presented an endothermic peak that indicates the melting point of 68.97 °C confirming the results of Andriotis and his co-authors (69 °C) ( Andriotis et al, 2020 ). The T onset was 66.45 °C, the T endset was 71.43 °C while the ΔH = 20.12 J/g.…”
Section: Compatibility Studiessupporting
confidence: 84%
“…9 ) can be highlighted in comparison with the excipients by the presence of the bands belonging to C = C and =C–H aliphatic groups (1582 and 1627 cm −1 ) ( Table 10 ). These two specific bands were observed also in the studies conducted by Andriotis et al ( Andriotis et al, 2020 ) In most of the cases the previously mentioned bands could be observed in the binary mixtures, the only exceptions being represented by CBD:PODTG2 ( Fig. 7 ) where a prominent band was observed at 1642 cm −1 .…”
Section: Compatibility Studiessupporting
confidence: 74%
See 1 more Smart Citation
“…The system consisted of a pump (LC-10 AD VP), an autosampler (SIL-20A HT), and an ultraviolet-visible detector (SPD-10A VP, Shimadzu, Kyoto, Japan). The chromatographic conditions were adapted from the literature, with modifications (30,39). The stationary phase for CBD was a Discovery HS C18 (15 cm x 4.6 mm, 3 µm) column and the mobile phase consisted of a mixture of (A) acetonitrile and (B) phosphate buffer (KH 2 PO 4 , 0.0126M, pH 5.0), A:B 80:20.…”
Section: High-performance Liquid Chromatography (Hplc)mentioning
confidence: 99%
“…Nevertheless, the oral route is the most common due to ease of administration. To this context, a wide range of formulations aimed for oral delivery has been reported including lipid-based delivery systems (SNEDDS), gastro retentive dosage forms, amorphous solid dispersions, and cyclodextrin inclusion complexes (27)(28)(29)(30)(31), focusing mainly to cannabinoids solubility enhancement effect.…”
Section: Introductionmentioning
confidence: 99%