2015 Second International Conference on Computing Technology and Information Management (ICCTIM) 2015
DOI: 10.1109/icctim.2015.7224601
|View full text |Cite
|
Sign up to set email alerts
|

Development of image error correction system for 3D optical microscope

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
3
1
1
1

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 2 publications
0
5
0
Order By: Relevance
“…In the stereo image alignment correction process, the left and right images are converted by homography matrix. The matched feature point pairs extracted using by Speeded-Up Robust Features algorithm in the left and right images are used to calculate the homography matrix [ 16 , 17 ]. After correcting the stereo image alignment, the vertical error of the matched feature points was 0%, the rotational error was 1.1°, and the zoom size error was 2%.…”
Section: Methodsmentioning
confidence: 99%
“…In the stereo image alignment correction process, the left and right images are converted by homography matrix. The matched feature point pairs extracted using by Speeded-Up Robust Features algorithm in the left and right images are used to calculate the homography matrix [ 16 , 17 ]. After correcting the stereo image alignment, the vertical error of the matched feature points was 0%, the rotational error was 1.1°, and the zoom size error was 2%.…”
Section: Methodsmentioning
confidence: 99%
“…A polarizing film was attached on the prism surface and a 1/4 λ wave plate was placed between the prism and the curved mirror to minimize optical power loss. To reduce the weight of optical module, poly methyl methacrylate (PMMA) was used in the fabrication of the optical prisms and curved mirror, and the outside of the effective optical path was cut as shown in [16][17]. After correcting the stereo image alignment, the vertical error of the matched feature points was 0%, the rotational error was 1.1°, and the zoom size error was 2%.…”
Section: Stereoscopic Microscopementioning
confidence: 99%
“…However, it had the image output error. The image output error of our optical microscope occurred in the cause of the refractive image on the mirrors [6]. The error was generated the image is not projected on the centre point of the camera's sensor because of refraction error of mirrors.…”
Section: Image Output Error Of the Optical Microscopementioning
confidence: 99%
“…Figure 5 shows to correct stereo images using checker. If there is not the checker image, then it should be used other method [6]. We changed Third step in the method described above.…”
Section: Stereo Image Correction For 3d Optical Microscopementioning
confidence: 99%
See 1 more Smart Citation