Proceedings of the 12th International Joint Conference on Biomedical Engineering Systems and Technologies 2019
DOI: 10.5220/0007523802200227
|View full text |Cite
|
Sign up to set email alerts
|

Development of Integrated Electrochemical–QuartzCrystal Microbalance Biosensor Arrays: Towards Ultrasensitive, Multiplexed and Rapid Point-of-Care Dengue Detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 0 publications
1
6
0
Order By: Relevance
“…This aligns with other reports of the more sensitive EIS lowering the LOD of the overall detection system. 39,41,73 These detection limits are 1−2 orders of magnitude better than some recent biosensing attempts of exosomes, all while being conducted in complex media. 74−78 Overall, these results underline the capability of the EQCM-D based immunosensor to effectively discern CD63-positive exosomes in a sensitive and specific manner.…”
Section: ■ Results and Discussionmentioning
confidence: 87%
See 2 more Smart Citations
“…This aligns with other reports of the more sensitive EIS lowering the LOD of the overall detection system. 39,41,73 These detection limits are 1−2 orders of magnitude better than some recent biosensing attempts of exosomes, all while being conducted in complex media. 74−78 Overall, these results underline the capability of the EQCM-D based immunosensor to effectively discern CD63-positive exosomes in a sensitive and specific manner.…”
Section: ■ Results and Discussionmentioning
confidence: 87%
“…This aligns with other reports of the more sensitive EIS lowering the LOD of the overall detection system. 39 , 41 , 73 These detection limits are 1–2 orders of magnitude better than some recent biosensing attempts of exosomes, all while being conducted in complex media. 74 78 …”
Section: Resultsmentioning
confidence: 88%
See 1 more Smart Citation
“…The acquired correlation of QCM response and ELISA result was 0.73. Zainuddin et al (2019) had developed a portable QCM device that connects with open-source software and hardware platform (OpenQCM). The system had achieved a low limit of detection of 10 ng/mL, and the DENV identification test can be performed within 30 min.…”
Section: Quartz Crystal Microbalance (Qcm)mentioning
confidence: 99%
“…Reaffirming the importance and need for an early diagnosis of dengue, Zainuddin et al [25] proposed the construction of an integrated system for the ultrasensitive detection of dengue virus measuring both mass and impedance as transduction signals. Named electrochemical quartz crystal microbalance biosensor, this kind of device combines the high sensitivity of piezoelectric measurements with the high selectivity and linearity provided by electrochemical techniques (besides serving as its own cross-validation method).…”
Section: Denguementioning
confidence: 99%