2017
DOI: 10.1007/s10527-017-9641-7
|View full text |Cite
|
Sign up to set email alerts
|

Development of Medical and Technical Requirements and Simulation of the Flow−Pressure Characteristics of the Sputnik Pediatric Rotary Blood Pump

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
6
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(8 citation statements)
references
References 6 publications
2
6
0
Order By: Relevance
“…This way the flow must be evenly distributed between the pulmonary arteries, considering the reduction of the system power loss with the RBP connected for the auxiliary blood circulation. The analysis carried out in this work and many similar studies performed by other groups [19][20][21][23][24][25] shows that the blood flow in TCPC is formed by the flow geometry configuration. First, as it is shown for TCPC-1 and TCPC-2 configurations, the blood flow coming from IVC is mixed directly with the flow from the SVC at the TCPC junction.…”
Section: Discussionsupporting
confidence: 67%
See 3 more Smart Citations
“…This way the flow must be evenly distributed between the pulmonary arteries, considering the reduction of the system power loss with the RBP connected for the auxiliary blood circulation. The analysis carried out in this work and many similar studies performed by other groups [19][20][21][23][24][25] shows that the blood flow in TCPC is formed by the flow geometry configuration. First, as it is shown for TCPC-1 and TCPC-2 configurations, the blood flow coming from IVC is mixed directly with the flow from the SVC at the TCPC junction.…”
Section: Discussionsupporting
confidence: 67%
“…The analysis carried out in this work and many similar studies performed by other groups shows that the blood flow in TCPC is formed by the flow geometry configuration. First, as it is shown for TCPC‐1 and TCPC‐2 configurations, the blood flow coming from IVC is mixed directly with the flow from the SVC at the TCPC junction.…”
Section: Discussionsupporting
confidence: 57%
See 2 more Smart Citations
“…The authors noted that the lowest rotation speed necessary to maintain the hemodynamics appropriate for a young child could cause clot formation. This is the principal reason for using a VAD outside its operating ranges, which causes fundamental changes to blood flow in the pump leading to the formation of backflows and stasis zones and resultant thrombus formation .…”
mentioning