Development of multichord ion Doppler spectroscopy system for toroidal flow measurement of field-reversed configuration

Abstract: A double-chord ion Doppler spectroscopy (IDS) system was developed to measure the ion temperature and flow velocity of field-reversed configuration (FRC) plasmas in the FRC amplification via a translation-collisional merging (FAT-CM) device. Adopting a Czerny–Turner mount monochromator and 16-channel photomultiplier tube array, the developed IDS system achieves high wavelength resolution and fast time response. In addition, two vertically aligned optical paths share the optical system up to the monochromator a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

3
1

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 12 publications
0
4
0
Order By: Relevance
“…In this investigation, Doppler spectroscopy of impurity carbon spectra (C III and C V ) is used to estimate ion temperature. 21 Here, the relaxation times of deuterium with carbon (C III ) is approximately 2.5 ls and with C V is 0.6 ls. Subsequently, the temperature decreases relatively quickly, while the magnetic flux and total energy gradually decrease but remain twice as high compared to the case without the second merging.…”
mentioning
confidence: 84%
“…In this investigation, Doppler spectroscopy of impurity carbon spectra (C III and C V ) is used to estimate ion temperature. 21 Here, the relaxation times of deuterium with carbon (C III ) is approximately 2.5 ls and with C V is 0.6 ls. Subsequently, the temperature decreases relatively quickly, while the magnetic flux and total energy gradually decrease but remain twice as high compared to the case without the second merging.…”
mentioning
confidence: 84%
“…Two interferometers for electron density measurement were installed at the formation section (z ∼ 2.1 m) and the confinement section (z ∼ −0.6 m) [25]. Ion temperature and toroidal flow were measured using the ion Doppler spectroscopy (IDS) system [26] at the formation section (z ∼ 2.1 m). Radial motion was observed by a set of two tomography cameras (T-cams) that we have developed [27,28].…”
Section: Fat Devicementioning
confidence: 99%
“…The line-integrated electron density is measured using a quadrature interferometer [17]. In addition, the ion temperature (T i ) is assessed using ion Doppler spectrometry [18], whereas the total temperature (T t = T i + T e ) is derived from radial pressure balance: B z 2 /2µ 0 + p = B e 2 /2µ 0 . We obtained the volume-averaged beta <β⩾ 1−(r s /r w ) 2 /2 from the equation…”
Section: Sequential Injection Of Two Frcsmentioning
confidence: 99%