2018
DOI: 10.1016/j.sbsr.2018.05.001
|View full text |Cite
|
Sign up to set email alerts
|

Development of printed and flexible dry ECG electrodes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

2
80
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 160 publications
(82 citation statements)
references
References 34 publications
2
80
0
Order By: Relevance
“…Therefore, high-quality electrodes are significant for precisely monitoring the physiological parameters of the human body. At present, ECG, EEG, electromyogram (EMG), or electro-ophthalmogram (EOG) signals are measured on a standard silver/silver chloride (Ag/AgCl) wet electrode for medical diagnosis [1]. Such electrodes usually reduce the contact impedance between the skin and electrode by using conductive gels [1].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Therefore, high-quality electrodes are significant for precisely monitoring the physiological parameters of the human body. At present, ECG, EEG, electromyogram (EMG), or electro-ophthalmogram (EOG) signals are measured on a standard silver/silver chloride (Ag/AgCl) wet electrode for medical diagnosis [1]. Such electrodes usually reduce the contact impedance between the skin and electrode by using conductive gels [1].…”
Section: Introductionmentioning
confidence: 99%
“…At present, ECG, EEG, electromyogram (EMG), or electro-ophthalmogram (EOG) signals are measured on a standard silver/silver chloride (Ag/AgCl) wet electrode for medical diagnosis [1]. Such electrodes usually reduce the contact impedance between the skin and electrode by using conductive gels [1]. Standard Ag/AgCl wet electrodes enable low electrode-skin contact impedance and the acquisition of signals with high stability and repeatability.…”
Section: Introductionmentioning
confidence: 99%
“…In this approach, several electrodes are realized on an earplug and conduct the electrical cortical signal in the auditory canal and the auricle. Concepts range from flexible silicone plugs with conductive silicones or coatings [8][9][10] to hard shells that are adapted to the respective ears with individually attached electrodes that have been cut out or metal pastes that have been applied manually [2,12]. Especially, porous silver chloride is often used, which degrades over time, and conductive gel [11] must be used for acceptable measurements, which excludes long-term measurements, as this dries out over time.…”
Section: Introductionmentioning
confidence: 99%
“…In modern medical applications, the desire for efficient biomedical systems along with the problem of increasing health costs has moti-vated the development of biopotential electrodes [1,3], smart bio-sensing devices [4], smart textile materials [5] [6], microelectronics circuits [7] and smart wireless communications techniques [8].…”
Section: Introductionmentioning
confidence: 99%
“…One of the earliest works that examined ECG electrode for biometric systems dates back to 1977 [6]. However, a clean ECG signal requires the use of clean room facilities and bulky equipment thereby making the manufacturing process relatively expensive and time-consuming [7]. In general, healthy ECG heartbeat has six characteristic or fiducial points, namely P, Q, R, S, T, and U.…”
Section: Introductionmentioning
confidence: 99%