Development of semi-automated system for preparation of 188Re aqueous solutions of high and reproducible activity concentrations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2005
2005
2020
2020

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 23 publications
(11 citation statements)
references
References 13 publications
0
11
0
Order By: Relevance
“…Further, personnel exposures may be reduced by automation or semiautomation of generator operation. 70,71 The consequences of the high activity levels of such a high beta-energy emitting radionuclide should not be underestimated, and the radiological protection issues required to minimize radiation dose to personnel are important in using this generator system. In addition to the bremsstrahlung radiation from interaction with the high energy 2.12 MeV beta particle, as shown in Figure 6, there are also several highenergy gamma-rays emitted by 188 Re that complicate the shielding requirements for and gamma camera imaging of this isotope.…”
Section: Radiation Safety and Shielding Requirementsmentioning
confidence: 99%
“…Further, personnel exposures may be reduced by automation or semiautomation of generator operation. 70,71 The consequences of the high activity levels of such a high beta-energy emitting radionuclide should not be underestimated, and the radiological protection issues required to minimize radiation dose to personnel are important in using this generator system. In addition to the bremsstrahlung radiation from interaction with the high energy 2.12 MeV beta particle, as shown in Figure 6, there are also several highenergy gamma-rays emitted by 188 Re that complicate the shielding requirements for and gamma camera imaging of this isotope.…”
Section: Radiation Safety and Shielding Requirementsmentioning
confidence: 99%
“…The standard alumina-based generator is eluted with saline at a slow flow-rate of typically 1–2 mL/min., with the volume based on the size of the generator (i.e., “void volume”) to insure complete removal of the 188 Re bolus. Some institutions have instituted the use of semi- or totally-automated elution systems (4648). These methods have helped move use of the generator forward, and are important to insure reproducible results and reduce the user radiation burden.…”
Section: Re Productionmentioning
confidence: 99%
“…However, due to the low specific activity of 188 W, the 188 Re obtained from 188 W/ 188 Re generators is eluted with low radioactivity concentration. For this reason, it often needs an additional concentration step for therapeutic applications [ 11 , 12 , 13 , 14 , 15 , 16 ]. Alternative pathways such as 188 W/ 188 Re gel generators based on zirconium or titanium wolframate, have also been exploited [ 17 , 18 ], however nowadays most of the commercial 188 W/ 188 Re generators are based on alumina as sorbent on the column.…”
Section: Rhenium-188mentioning
confidence: 99%