Development of Solid-state Reference Electrode Based on Sodium Polyanethol Sulfonate Immobilised on Cellulose Acetate

Abstract: 52.4 ± 0.4, 51.4 ± 0.4, and −52.3 ± 0.9

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
14
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(14 citation statements)
references
References 51 publications
0
14
0
Order By: Relevance
“…4d, the CV image that is by boiling for 120 min, there is no visible peak of oxidation in the area of −1-1 V and the resulting CV shape is typical of the CV shape of graphite electrodes. 22,23 Under these circumstances, the electrode chosen to be NO 3 -ISE is boiled for 120 min. In this study, boiling above 120 min was not carried out, this is due to the CV at 120 min had fulfilled the characteristics of graphite electrodes.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…4d, the CV image that is by boiling for 120 min, there is no visible peak of oxidation in the area of −1-1 V and the resulting CV shape is typical of the CV shape of graphite electrodes. 22,23 Under these circumstances, the electrode chosen to be NO 3 -ISE is boiled for 120 min. In this study, boiling above 120 min was not carried out, this is due to the CV at 120 min had fulfilled the characteristics of graphite electrodes.…”
Section: Resultsmentioning
confidence: 99%
“…The PPy-NO 3 formed on the surface of both graphite electrodes form an aggregation of grapes like a pile of grapes and this matches the characteristics of the PPy particles from previous studies. 22 Figure 8 also shows PPy-NO 3 formed on the surface of the graphite rod surface is denser than the carbon paste graphite rod from the dry battery waste. This is due to differences in the surface contours of the graphite electrodes used.…”
mentioning
confidence: 96%
See 1 more Smart Citation
“…The anion may enter the membrane, thus, the drop of the potential differences. 1 mV/h [48]. Therefore, this system displays good stability in the first 10 h. The leaching of lipophilic salt caused a higher drift of potential differences after 10 h, KTClPB from the pseudo-reference electrode, and NaTFPB from aluminium ion sensor into aqueous solution [29].…”
Section: Stabilitymentioning
confidence: 92%
“…Meanwhile, the potential differences at the 15th to 24th hour gave a drift of 6.47 ± 0.40% (2.16 ± 0.16 mV/h). The drift rate of a suitable reference electrode should not exceed 1 mV/h [48]. Therefore, the potassium ion sensor can be said to display excellent stability in the first 10 h. A higher drift rate occurred after 10 h because of the leaching of lipophilic salt, KTClPB, into aqueous solution [29].…”
Section: Performances Assessment Of Potassium Ion Sensor For Pseudo-rmentioning
confidence: 99%