2023
DOI: 10.1016/j.conbuildmat.2023.133093
|View full text |Cite
|
Sign up to set email alerts
|

Development of sustainable heat resistive and storage panels for building envelope: An experimental and numerical study

Dileep Kumar,
Morshed Alam,
Jay G. Sanjayan
Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 59 publications
0
3
0
Order By: Relevance
“…In the case of internal insulation of the enclosing structure (before the structural layer), it is intuitively clear that the amount of accumulated heat by the most heat-intensive structural layer cannot equal the value obtained with classical external insulation (after the structural layer), which is also confirmed by the results obtained in [19]. Indeed, the value of the relative excess temperature of the structural layer (formula (9), in the case of internal insulation, will be low. Consequently, the reduced heat capacity of an external multilayer enclosing structure with the internal insulation will be much less, compared to a similar enclosing structure with the external insulation (formula (8).…”
Section: Discussionmentioning
confidence: 60%
See 1 more Smart Citation
“…In the case of internal insulation of the enclosing structure (before the structural layer), it is intuitively clear that the amount of accumulated heat by the most heat-intensive structural layer cannot equal the value obtained with classical external insulation (after the structural layer), which is also confirmed by the results obtained in [19]. Indeed, the value of the relative excess temperature of the structural layer (formula (9), in the case of internal insulation, will be low. Consequently, the reduced heat capacity of an external multilayer enclosing structure with the internal insulation will be much less, compared to a similar enclosing structure with the external insulation (formula (8).…”
Section: Discussionmentioning
confidence: 60%
“…With an excess of heat, accumulation (accumulation) occurs, with a shortage, return. For the effective accumulation of heat/cold, provided that the internal air temperature is maintained within the normalized values, enclosing structures have been proposed, which include substances with a phase transition [4][5][6][7][8][9][10][11][12][13]. In the case of intermittent operation of heating (cooling) systems, the heat storage capacity is directly taken into account to improve the accuracy of calculations [11][12].…”
Section: Introductionmentioning
confidence: 99%
“…Electricity emissions factors of electricity generation in different states of Australia[53,58]. The emissions factors is the sum of scope 2 and scope 3 emissions of purchased electricity from a grid.…”
mentioning
confidence: 99%