1969
DOI: 10.1136/bmj.4.5682.545-a
|View full text |Cite
|
Sign up to set email alerts
|

Device for continuous monitoring of cerebral activity in resuscitated patients.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
104
0
2

Year Published

1985
1985
2021
2021

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 240 publications
(106 citation statements)
references
References 3 publications
0
104
0
2
Order By: Relevance
“…Thickness of the tracing is proportional to the moment-to-moment amplitude variability, while the overall magnitude of the tracing reflects the voltage amplitude of the EEG at each period of time. For example, burst-suppression would result in a thick tracing due to alternating bursts and suppressions, whereas amplitude increases during seizure may result in increase in the overall magnitude of the tracing [111]. Electrodecremental seizures or decrease in EEG amplitudes during anesthesia may result in the opposite effect.…”
Section: Quantitative Tools and Technical Methodsmentioning
confidence: 99%
“…Thickness of the tracing is proportional to the moment-to-moment amplitude variability, while the overall magnitude of the tracing reflects the voltage amplitude of the EEG at each period of time. For example, burst-suppression would result in a thick tracing due to alternating bursts and suppressions, whereas amplitude increases during seizure may result in increase in the overall magnitude of the tracing [111]. Electrodecremental seizures or decrease in EEG amplitudes during anesthesia may result in the opposite effect.…”
Section: Quantitative Tools and Technical Methodsmentioning
confidence: 99%
“…Data were filtered, rectified, and integrated over a window of 100 ms. To eliminate nonphysiological signal components and to slightly attenuate the dominant delta-wave patterns, a series of filters were applied to mimic those used in the Cerebral Function Monitor (24). The final signal was plotted logarithmically, and the resulting aEEG was analyzed by two different methods: a quantitative mean aEEG background technique, and a qualitative neural activity score technique.…”
Section: Methodsmentioning
confidence: 99%
“…Unlike in [21], the Amplitude Integrated EEG (aEEG) is widely used to detect neonatal seizures, despite the fact that the accuracy of seizure recognition can be moderate, especially in brief, low amplitude, focally oriented seizures [22]. Neonatologists analyze the aEEG signals at the patient's bedside.…”
Section: Related Work 31 Statistical Detectionmentioning
confidence: 99%