2002
DOI: 10.1006/jcis.2002.8254
|View full text |Cite
|
Sign up to set email alerts
|

Dewetting of Unreacted Epoxy/Amine Mixtures on Silica

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
7
0

Year Published

2008
2008
2020
2020

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(8 citation statements)
references
References 26 publications
1
7
0
Order By: Relevance
“…This indicates that the DGEBA molecular ion is not detected during the curing reaction at any of the HR ratios. This finding is in line with observation made by Woerdeman et al25 that the DGEBA ion is not detected when the curing reaction is complete. Figure 3(a) also indicates that the C x H y N + ions and the C 3 H 8 + ion feature in the opposite direction (positive) to all other significant ions of C 14 H 7 O + , CHO + , CH 3 O + , C 3 H 7 + , C 3 H 5 + , and C 24 H 21 O + This indicates a discrete physical phenomenon in which the ions in the positive region correspond to the change in hardener concentration while the other ions are related to the change in the resin concentration in the data set.…”
Section: Resultssupporting
confidence: 93%
See 1 more Smart Citation
“…This indicates that the DGEBA molecular ion is not detected during the curing reaction at any of the HR ratios. This finding is in line with observation made by Woerdeman et al25 that the DGEBA ion is not detected when the curing reaction is complete. Figure 3(a) also indicates that the C x H y N + ions and the C 3 H 8 + ion feature in the opposite direction (positive) to all other significant ions of C 14 H 7 O + , CHO + , CH 3 O + , C 3 H 7 + , C 3 H 5 + , and C 24 H 21 O + This indicates a discrete physical phenomenon in which the ions in the positive region correspond to the change in hardener concentration while the other ions are related to the change in the resin concentration in the data set.…”
Section: Resultssupporting
confidence: 93%
“…The peaks for data analysis were selected initially based on reference libraries and previous assignments in the literature for DGEBA, DGEBF, and IPD molecules 20, 21, 24, 25. Further, peaks were assigned using the library and the exact mass calculator tool incorporated in the Ionspec software package (Ion‐TOF GmbH, Germany) to identify contaminant peaks, including the hydrocarbon peaks, and peaks that were likely to correspond to fragments of the resin/hardener not listed in the literature.…”
Section: Methodsmentioning
confidence: 99%
“…This technique has previously been used on epoxy-amine surfaces to characterize the chemical components. [28] Results produced from the spectrometer indicate a high degree of bromine (m/z ¼ 79 and 81) on the entire surface, confirming release of the brominated epoxy monomer from the microcapsules leading to formation of a new film on the surface.…”
Section: Full Papermentioning
confidence: 95%
“…The peaks for ToF‐SIMS data analysis were selected initially on the basis of reference libraries and previous assignments in the literature for DGEBA, DGEBF, IPD, Teta, and other amine molecules 21–24. Further peaks were assigned with the library and the exact mass calculator tool in Ionspec software (Ion‐TOF), including contaminant peaks, hydrocarbon peaks, and peaks likely to correspond to fragments of the resin/hardener that were not listed in the literature.…”
Section: Methodsmentioning
confidence: 99%