1994
DOI: 10.2214/ajr.163.1.8010248
|View full text |Cite
|
Sign up to set email alerts
|

Diagnosis of breast implant rupture: imaging findings and relative efficacies of imaging techniques.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
41
0
5

Year Published

1996
1996
2014
2014

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 110 publications
(47 citation statements)
references
References 0 publications
1
41
0
5
Order By: Relevance
“…In case of rupture, it was determined whether the silicone was contained within the fibrous capsule surrounding the implant (intracapsular rupture) or had escaped outside the boundaries of the normal fibrous capsule (extracapsular rupture). 20 Details about image evaluation and the criteria for rupture diagnosis have been described in detail previously. 4 …”
Section: Mri Evaluationmentioning
confidence: 99%
See 1 more Smart Citation
“…In case of rupture, it was determined whether the silicone was contained within the fibrous capsule surrounding the implant (intracapsular rupture) or had escaped outside the boundaries of the normal fibrous capsule (extracapsular rupture). 20 Details about image evaluation and the criteria for rupture diagnosis have been described in detail previously. 4 …”
Section: Mri Evaluationmentioning
confidence: 99%
“…A small pilot study prior to the first MRI revealed a sensitivity of 86% and a specificity of 100% for rupture diagnosis, 4 which is in good accordance with other studies in this area. 20,[23][24][25][26] Because we deliberately decided to have a high specificity rather than a high sensitivity in this study, some ruptures may have been overlooked. We know from surgical reports on explantations among study participants that there were virtually no false-positive results (1 falsepositive rupture in 60 women who underwent surgery either after the first or second MRI).…”
Section: Commentmentioning
confidence: 99%
“…----Implant [55] Breast [54,56] Ultrasound Ultrasound Figure 1 The volume measurements were further categorised according to the underlying mechanisms. Of each method, the settings (device, illustration, patient position), reliability (reproducibility), feasibility (time and cost) and application (list of articles that used similar methods) were analysed.…”
Section: Resultsmentioning
confidence: 99%
“…Die Sensitivität im Nachweis von Implantatrupturen variiert in Studien zwischen 23 und 55% [7,12,13] .…”
Section: Introductionunclassified
“…Im Vergleich zu anderen bildgebenden Verfahren weist sie eine hohe Sensitivität von 76-95% und Spezifität von 93-97% im Nachweis von Implantatrupturen auf [6,[12][13][14] .…”
Section: Introductionunclassified