Lithium Ion Batteries - New Developments 2012
DOI: 10.5772/26749
|View full text |Cite
|
Sign up to set email alerts
|

Diagnosis of Electrochemical Impedance Spectroscopy in Lithium-Ion Batteries

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
70
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 74 publications
(72 citation statements)
references
References 90 publications
2
70
0
Order By: Relevance
“…The EIS data for various electrodes used in LIBs are listed in Table 2. for all electrodes are increased after 10th discharging because of continuous SEI formation on the surface of the particles [34,35]. The ct values of the LIBs with the fresh NCA, NCA-Mn, and NCA-Ti electrodes are 191.9, 159.2, and 124.2 Ω, respectively, while the corresponding values after 10 cycles are 357.9, 300.8, and 238.4 Ω.…”
Section: Resultsmentioning
confidence: 83%
See 1 more Smart Citation
“…The EIS data for various electrodes used in LIBs are listed in Table 2. for all electrodes are increased after 10th discharging because of continuous SEI formation on the surface of the particles [34,35]. The ct values of the LIBs with the fresh NCA, NCA-Mn, and NCA-Ti electrodes are 191.9, 159.2, and 124.2 Ω, respectively, while the corresponding values after 10 cycles are 357.9, 300.8, and 238.4 Ω.…”
Section: Resultsmentioning
confidence: 83%
“…Nyquist plots of the fresh NCA, NCA-Mn, and NCATi electrodes and the electrodes after the 10th cycle are shown in Figure 8. Experimental results shown in solid lines are fitted by the equivalent circuit in the inset of Figure 8 Journal of Nanomaterials [32][33][34][35][36]. The Nyquist plots exhibit identical electrochemical behaviors with semicircles in the high-frequency region and a straight sloping line at low frequencies.…”
Section: Resultsmentioning
confidence: 99%
“…For instance see Figure 6 of Reference 15, as well as many others. 2,3,16 So far, many formulas were shown, but in order to demonstrate that they work in a real example, Figure 9 uses the code to convert from a Voight configuration (with a series capacitor) to a ladder configuration (with a capacitor embedded in the inner part of the ladder). Figure 9c shows the two circuits considered.…”
Section: Resultsmentioning
confidence: 99%
“…EIS often becomes a technique of choice to study the electrified interface and hence has been used in lithium ion batteries. Briefly, the EIS literature on lithium 6 ion batteries may be represented by typical papers such as those by Zhuang et al [14] and Chagnes et al [15]. Chang et al [16] have described and discussed the development of new EIS methods to reduce measurement time.…”
Section: Introductionmentioning
confidence: 99%