2017
DOI: 10.1016/j.pan.2017.03.002
|View full text |Cite
|
Sign up to set email alerts
|

Diagnosis of exocrine pancreatic insufficiency in chronic pancreatitis: 13C-Mixed Triglyceride Breath Test versus Fecal Elastase

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
21
0
2

Year Published

2017
2017
2022
2022

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 36 publications
(23 citation statements)
references
References 38 publications
0
21
0
2
Order By: Relevance
“…The monoclonal ELISA assay is considered to be more accurate than the polyclonal test for FE-1 [26]. The sensitivity and specificity of FE-1 for diagnosing PI improves when a cut-off concentration of b 128 μg/g stool is utilized [27], with a recent study reporting that 84 μg/g stool has even higher diagnostic accuracy with a sensitivity of 87.5%, specificity of 81.6%, PPV 66.7%, NPV 93.9%, and AUC of 0.861 when compared to 72 h fecal fat estimation [28]. Others note that a level N 100 μg/g stool has a 99% predictive value for the subject not being PI [29].…”
Section: Indirect Testsmentioning
confidence: 99%
“…The monoclonal ELISA assay is considered to be more accurate than the polyclonal test for FE-1 [26]. The sensitivity and specificity of FE-1 for diagnosing PI improves when a cut-off concentration of b 128 μg/g stool is utilized [27], with a recent study reporting that 84 μg/g stool has even higher diagnostic accuracy with a sensitivity of 87.5%, specificity of 81.6%, PPV 66.7%, NPV 93.9%, and AUC of 0.861 when compared to 72 h fecal fat estimation [28]. Others note that a level N 100 μg/g stool has a 99% predictive value for the subject not being PI [29].…”
Section: Indirect Testsmentioning
confidence: 99%
“…PEI can also be diagnosed with a 13C mixed triglyceride breath test by measuring the concentration of 13CO 2 in expired air after administering the radiolabeled test meal containing a known amount of fat [86]. Its accuracy is similar to FE-1 in diagnosing PEI [87].…”
Section: Diagnosis Of Peimentioning
confidence: 99%
“…There are several direct and indirect diagnostic methods for EPI but only the 13C-mixed triglyceride breath test is recommended by the FDA in clinical trials as a gold standard [17]. Recently, González-Sánchez et al found that the diagnostic performance of fecal elastase-1 and 13C-mixed breath test was similar in chronic pancreatitis patients in terms of EPI diagnosis [18]. Beside this recommendation and in the light of this information fecal elastase-1 is still reliable for EPI diagnosis.…”
Section: Discussionmentioning
confidence: 99%