2010 Annual International Conference of the IEEE Engineering in Medicine and Biology 2010
DOI: 10.1109/iembs.2010.5626230
|View full text |Cite
|
Sign up to set email alerts
|

Diagnosis of foot-and-mouth disease by electrochemical enzyme-linked immunoassay

Abstract: The development of an inmunosensor for the point-of-care detection of the foot-and-mouth cattle disease is presented. The detector is based on an ELISA method with electrochemical detection. A non-structural protein, 3ABC, is used to selectively detect antibodies is used to selectively detect anti-3ABC antibodies produced after infection. The biological test is performed onto a screen printed electrodes. A dedicated small, portable potentiostat is employed for the control of the sensors, as well as data acquis… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
2
2
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 2 publications
0
4
0
Order By: Relevance
“…Commercial carbon ink (Dupont BQ242), Ag ink (Dupont 5025) and Ag/AgCl ink (Dupont 5870) were employed. Others details of materials and manufacturing process are presented in [4]. …”
Section: Developmentmentioning
confidence: 99%
“…Commercial carbon ink (Dupont BQ242), Ag ink (Dupont 5025) and Ag/AgCl ink (Dupont 5870) were employed. Others details of materials and manufacturing process are presented in [4]. …”
Section: Developmentmentioning
confidence: 99%
“…A non-structural protein i.e. 3ABC of associated disease was detected through specific antibodies by utilization of a screen-printed electrode (Longinotti et al 2010 ). Hydatid disease is associated with Echinococcus granulosis.…”
Section: Development Of Nano-biosensing Devices For Detection Of Animmentioning
confidence: 99%
“…The important distinction of immunosensor assays is the method of signal transduction which may employ either an electrochemical or an optical transducer [ 20 ]. In electrochemical transducers, an electrochemical signal is measured, the magnitude of which changes following the formation of the Ag-Abs complex [ 21 , 22 ]. In the case of optical transducers, Ag-Abs quantification is based on the generation of light signals (color change or fluorescence) or changes in the optical properties of the environment [ 23 ].…”
Section: Introductionmentioning
confidence: 99%