Abstract:Abstract. This paper dealing with diagnosis of induction machines affected by combined eccentricity via analyzing the sator curents, inspection of the current spectrums and predict the harmonics that present in the spectrums and represent an indication for this ailment . The machine under invistigation is a 400 kW, four pole-pair, squarelcage induction machine. The current spectrums were calculated for the cases of full symmetry and mixed eccentricity. The calculations presented in this paper, are based on the… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.