Abstract: This study aimed to evaluate the diagnostic ability and sectoral structure function relationship of circumpapillary vessel density (cpVD) and macular vessel density (mVD) with optical coherence tomography angiography (OCTA) in early glaucomatous (EG) eyes. 224 EG eyes of 167 patients (mean deviation (MD) > − 6 dB) and 70 normal eyes of 70 subjects were enrolled in this retrospective cross-sectional study. All patients underwent OCT and OCTA scanning. Diagnostic abilities were evaluated with area under recei… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
11
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 7 publications
(12 citation statements)
references
References 34 publications
1
11
0
Order By: Relevance
“…In support of wider field analysis, Akiyama et al reported that in early glaucoma eyes, a perifoveal annulus around the foveal avascular zone (with outer limits of 6 mm and inner of 3 mm) had a stronger structure-function relationship with VF than a smaller parafoveal annulus (outer limits of 3 mm, inner of 1 mm). 37 The current study's scan size could still be considered a limitation in that wider-field images were not obtained, which may have increased wedge identification, and the ability to quantify a larger proportion of wedge defects, however, this would have further reduced resolution and observable detail. Therefore, scan size and the analysis rigour must be noted when comparing results across studies.…”
Section: Discussionmentioning
confidence: 95%
See 1 more Smart Citation
“…In support of wider field analysis, Akiyama et al reported that in early glaucoma eyes, a perifoveal annulus around the foveal avascular zone (with outer limits of 6 mm and inner of 3 mm) had a stronger structure-function relationship with VF than a smaller parafoveal annulus (outer limits of 3 mm, inner of 1 mm). 37 The current study's scan size could still be considered a limitation in that wider-field images were not obtained, which may have increased wedge identification, and the ability to quantify a larger proportion of wedge defects, however, this would have further reduced resolution and observable detail. Therefore, scan size and the analysis rigour must be noted when comparing results across studies.…”
Section: Discussionmentioning
confidence: 95%
“…Previous studies often analyse the 3 × 3 mm scan which has a greater resolution than the 6 × 6 mm (cohort one) and 8.7 × 4.4 mm (cohort two) scans however, larger scan area was chosen to best visualise vascular wedge projection, despite the increase in capillary network detail from smaller scans which may influence overall density results. In support of wider field analysis, Akiyama et al reported that in early glaucoma eyes, a perifoveal annulus around the foveal avascular zone (with outer limits of 6 mm and inner of 3 mm) had a stronger structure–function relationship with VF than a smaller parafoveal annulus (outer limits of 3 mm, inner of 1 mm) 37 . The current study's scan size could still be considered a limitation in that wider‐field images were not obtained, which may have increased wedge identification, and the ability to quantify a larger proportion of wedge defects, however, this would have further reduced resolution and observable detail.…”
Section: Discussionmentioning
confidence: 95%
“…OCT and OCT angiography examinations were performed using the Cirrus HD 5000 OCT and the AngioPlex software (Version 11.0.0.29946; Carl Zeiss Meditec Inc.). The scanning speed was 68,000 A-scans per speed 42,43 . After pupil dilation with tropicamide and phenylephrine hydrochloride, high-quality circumpapillary OCT and OCT angiography scans were acquired by a trained operator in the same session, and the image with the best image quality was selected for subsequent analyses.…”
Section: Oct and Oct Angiography Measurementsmentioning
confidence: 99%
“…The Optic Disc Cube 200 × 200 scan protocol was used for cpRNFLT measurement 42,43 . Tracking of eye movements (Fast Trac) was applied during image acquisition.…”
Section: Oct and Oct Angiography Measurementsmentioning
confidence: 99%
“…OCT angiography (OCTA) is one of the most recent technologies which enables noninvasive imaging to quantify layer specific ocular microcirculation of the retina and choroid. Although several studies have shown the usefulness of evaluating circumpapillary vessel density (cpVD) in detecting focal glaucomatous changes of early glaucomatous eyes, 8 little is known about the potential of OCTA in HM eyes. There are reports of cpVD being reduced in HM eyes in comparison to eyes without HM, 9 suggesting the influence of AL elongation on OCTA parameters.…”
mentioning
confidence: 99%