Diagnostic Accuracy of Endocardial-to-Epicardial Myocardial Blood Flow Ratio for the Detection of Significant Coronary Artery Disease With Dynamic Myocardial Perfusion Dual-Source Computed Tomography

Abstract: limited response to vasodilator stress, resulting in globally reduced hyperemic MBF. 15 Because the endocardial layer is most susceptible to ischemia, 16,17 the ratio of endocardial MBF and epicardial MBF might be a more useful indicator of flow-limiting CAD.The purpose of this study was to investigate whether the transmural ratio of absolute MBF can improve the accuracy of CTP when compared with absolute MBF for the detection of flow-limiting CAD, as defined by fractional flow reserve (FFR). We also explored … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 13 publications
(8 citation statements)
references
References 39 publications
0
8
0
Order By: Relevance
“…Future developments. Two-compartment analysis might reduce underestimation of MBF by CT 163,164 , and the semiquantitative transmural perfusion ratio might improve diagnosis of myocardial ischaemia compared with using the MBF 165 . Low kilovolt scanning (70-80 kV) enables a substantial reduction in radiation dose, while increasing contrast-to-noise ratio 166 .…”
Section: Key Points For Echocardiographymentioning
confidence: 99%
“…Future developments. Two-compartment analysis might reduce underestimation of MBF by CT 163,164 , and the semiquantitative transmural perfusion ratio might improve diagnosis of myocardial ischaemia compared with using the MBF 165 . Low kilovolt scanning (70-80 kV) enables a substantial reduction in radiation dose, while increasing contrast-to-noise ratio 166 .…”
Section: Key Points For Echocardiographymentioning
confidence: 99%
“…Diagnostic performance of dynamic CTP has been validated against different reference standards including MRI [42][43][44][45], SPECT [43,46,47], and coronary angiography with FFR measurement [21,27,[48][49][50][51][52][53]. Available data are scarce on the diagnostic performance of dynamic CTP for detecting perfusion defects determined by MRI or SPECT.…”
Section: Diagnostic Performance Of Dynamic Ctpmentioning
confidence: 99%
“…In addition, hyperemic MBF in remote myocardium can be influenced by other factors such as age, gender, race, BMI, insulin resistance, arteriolar response to vasodilators, and presence of collateral vessels [54][55][56][57]. Debatably, relative MBF normalized by remote MBF may provide more accurate identification of hemodynamically significant CAD than abso-lute MBF [49,53]. We should also recognize that FFR is a measure of lesion specific hemodynamic significance of stenosis, not a measure of myocardial perfusion, which is governed by not only epicardial coronary stenosis, but also microvascular environment and collateral circulation.…”