Diagnostic Accuracy of Seven Commercial Assays for Rapid Detection of Group A Rotavirus Antigens

Abstract: Seven commercial immunochromatographic assays intended for the detection of group A rotavirus antigens in human stool samples were evaluated. These assays showed similar levels of diagnostic accuracy and were suitable for the detection of rotavirus in patients with acute gastroenteritis but missed some asymptomatic rotavirus shedding identified by real-time reverse transcription-PCR. Group A rotaviruses (RVA) are a leading cause of severe gastroenteritis in young children worldwide, with an estimated 450,000 d… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
19
1

Year Published

2016
2016
2021
2021

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 22 publications
(21 citation statements)
references
References 9 publications
1
19
1
Order By: Relevance
“…The sensitivity of both assays was in accordance with the results of previous studies using RT-PCR as reference standard [ 7 9 ]. This reduced sensitivity compared to what has been reported in the manufacturer inserts for both assays could be due to the lack of detection of certain genotypes by EIA and RDT.…”
Section: Discussionsupporting
confidence: 87%
See 3 more Smart Citations
“…The sensitivity of both assays was in accordance with the results of previous studies using RT-PCR as reference standard [ 7 9 ]. This reduced sensitivity compared to what has been reported in the manufacturer inserts for both assays could be due to the lack of detection of certain genotypes by EIA and RDT.…”
Section: Discussionsupporting
confidence: 87%
“…However, the 23 false negative specimens by both EIA and RDT were genotyped and showed the most frequent genotypes in our study (10 G2P[4], 8 G12P[8], 2 G3P[6], 2 G3+G9P[6] and 1 G9P[8]) [ 3 ], suggesting no clear association between lack of detection and particular genotypes. Instead, it is most probably due to the high sensitivity of the reference standard [ 8 , 9 ] and notably to the ability of RT-PCR to detect samples with low viral loads that cannot be detected by RDT and EIA assays [ 7 , 12 ]. Unfortunately, the rotavirus viral load in samples was not assessed during this study to confirm this hypothesis.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…This could be explained by the detection method used in the present study. Indeed, real-time RT-PCR has been demonstrated to be more sensitive than antigen detection by immunochromatographic test [ 41 ]. The circulating G and P genotypes showed a diverse pattern, with G9P[ 8 ] strains dominating.…”
Section: Discussionmentioning
confidence: 99%