2016
DOI: 10.1016/j.fusengdes.2016.02.008
|View full text |Cite
|
Sign up to set email alerts
|

Diagnostic development for current density profile control at KSTAR

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
16
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 22 publications
(17 citation statements)
references
References 12 publications
1
16
0
Order By: Relevance
“…It is the presence of the coherence terms in Eqs. (4)(5)(6)(7)(8)(9) that explains the asymmetry between the red-and blue-shifted lines for Stark effect measurement (note that the influence of field ionisation is still low [32] under these conditions). Therefore, for instance, depending on the orientation between the cathode rays and the vector direction of the electric field (e.g., parallel, α = 0; transverse, α = π/2; or anti-parallel, α = π) blue-shifted, red-shifted, or symmetric patterns were detected for Balmer-α components of the emission [17].…”
Section: Theoretical Approachmentioning
confidence: 99%
See 2 more Smart Citations
“…It is the presence of the coherence terms in Eqs. (4)(5)(6)(7)(8)(9) that explains the asymmetry between the red-and blue-shifted lines for Stark effect measurement (note that the influence of field ionisation is still low [32] under these conditions). Therefore, for instance, depending on the orientation between the cathode rays and the vector direction of the electric field (e.g., parallel, α = 0; transverse, α = π/2; or anti-parallel, α = π) blue-shifted, red-shifted, or symmetric patterns were detected for Balmer-α components of the emission [17].…”
Section: Theoretical Approachmentioning
confidence: 99%
“…Here we report the line intensities of the Lyman-α, β and Balmer-α lines for different values of α (Figs. [4][5][6]. The angle between the line-of-sight and the direction of the electric field is θ = π/2.…”
Section: Lines Ratio Of Stark Components In the Low Density Limitmentioning
confidence: 99%
See 1 more Smart Citation
“…KSTAR recently show cased its capabilities by setting a new record for long pulse Hmode operation [3], however to support the ITER project in exploring advanced scenarios, current profile measurements are of essence. For this reason, a 25 chord MSE polarimeter has been installed in 2015 [4] and commissioned during the 2015 plasma campaign. Owing to the digital data acquisition system combined with digital lockin analysis, the full Stokes vector is reconstructed on a millisecond timescale.…”
Section: Introductionmentioning
confidence: 99%
“…In this report, after giving an overview of the experimental setup at KSTAR, a generic twostep calibration and verifica tion method is presented: First the bandpass filters used to single out the redshifted Stark peak are calibrated such, that the measured pitch angle displays a physically reasonable slope. In the second step it is investigated whether systematic offsets are present by comparing the reconstructed qprofile 1,4 (constrained by MSE) against rational qvalues obtainable from independent diagnostics during MHD instabilities in the plasma. After successful calibration, the qprofile evolution of a sawtooth crash is analysed in section 4.…”
Section: Introductionmentioning
confidence: 99%