2014
DOI: 10.1111/resp.12334
|View full text |Cite
|
Sign up to set email alerts
|

Diagnostic properties of the methacholine and mannitol bronchial challenge tests: A comparison study

Abstract: The present study demonstrated overall similar diagnostic properties of two diagnostic tests, but also suggested their intercomplementary roles for asthma. The clinical trial registration number at ClinicalTrial.gov is NCT02104284.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0
4

Year Published

2015
2015
2023
2023

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 18 publications
(14 citation statements)
references
References 30 publications
0
10
0
4
Order By: Relevance
“…For this reason, methacholine may be used as a pharmaceutical in broncho provocation tests for the detection of bronchial reactivity 3,10,15 and also for this reason we used it in this clinical trial, as a drug that provokes bronchoconstriction.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…For this reason, methacholine may be used as a pharmaceutical in broncho provocation tests for the detection of bronchial reactivity 3,10,15 and also for this reason we used it in this clinical trial, as a drug that provokes bronchoconstriction.…”
Section: Discussionmentioning
confidence: 99%
“…Through this test, the drug causes bronchoconstriction and people with pre-existing airway hyperreactivity, such as asthmatics, will react to lower doses of drug. Methacholine inhalation test also helps in the assesment of disease severity [15][16][17] . With this research we expect to demonstrate that bronchoconstrictor effects of methacholine in patients with asthma are reduced if the patient has previously inhaled benzodiazepine.…”
mentioning
confidence: 99%
“…Compared to treatment guidelines based upon symptoms and lung function, treatment strategies targeting reductions in AHR to mannitol (STAMINA trial) (28) or methacholine (AMPUL trial) (9) both lead to improvements in the number of mild exacerbations. Mannitol appears more specific in detecting a diagnosis of asthma although it is less sensitive than methacholine (27, 29, 30). Interestingly, the biggest distinction may be in the effect of allergen exposure with increased responsiveness to methacholine but reduced responsiveness to mannitol three hours after allergen challenge (31).…”
Section: Measurement Of Ahr: To What Do We Respond and How Do We Mmentioning
confidence: 99%
“…It has a high sensitivity but a low specificity for active asthma and a low sensitivity to recognize EIB (29, 50). Mannitol test can reproduce the “osmolar” mechanism of EIA/EIB, through the osmotic action of this agent, demonstrating sensitivity and specificity comparable to the MCH for the diagnosis of EIA/EIB (29, 51, 52). Another effective test, made by ventilating dry air with CO 2 for 6 min through a low-resistance circuit at a rate higher than that usually realized during maximum exercise, is the EVH test (19).…”
Section: Diagnosismentioning
confidence: 93%