2010
DOI: 10.1007/s00423-010-0723-1
|View full text |Cite
|
Sign up to set email alerts
|

Diagnostic value of thyroglobulin measurement in fine-needle aspiration biopsy for detecting metastatic lymph nodes in patients with papillary thyroid carcinoma

Abstract: FNA-Tg measurement can be performed safely for the detection of lymph node metastasis in patients with differentiated thyroid carcinomas.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
43
1
1

Year Published

2012
2012
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 51 publications
(46 citation statements)
references
References 18 publications
1
43
1
1
Order By: Relevance
“…The technique accuracy, highly dependent on the experience and ability of the cytopathologist, has been reported to vary from 73% to 94% [17,18,22,25]. Over the last years, following clinical evidence showing that FNAB-Tgp in fine-needle washout improves the accuracy of FNAB-C in the evaluation of CLN metastases of DTC, it has been recommended the routine association of FNAB-Tgp with FNAB-C in the preoperative diagnosis of suspicious CLN [6,7,14-27,33].…”
Section: Discussionmentioning
confidence: 99%
“…The technique accuracy, highly dependent on the experience and ability of the cytopathologist, has been reported to vary from 73% to 94% [17,18,22,25]. Over the last years, following clinical evidence showing that FNAB-Tgp in fine-needle washout improves the accuracy of FNAB-C in the evaluation of CLN metastases of DTC, it has been recommended the routine association of FNAB-Tgp with FNAB-C in the preoperative diagnosis of suspicious CLN [6,7,14-27,33].…”
Section: Discussionmentioning
confidence: 99%
“…Accordingly, different FNA-Tg cutoff was proposed in the presence (36 μg/L) or absence (1.7 μg/L) of thyroid [31]. Meanwhile, two different papers found a unique accurate threshold of 0.93 ng/punction [22] and 28.5 μg/L [23]. However, among 114 and 225 consecutive patients, they enrolled 11% and 35% DTC patients before surgery, respectively.…”
Section: Clinical Data From Literaturementioning
confidence: 99%
“…In various studies, the volume of fluid used to wash the FNA needle ranges from 0.5 to 3.0 mL, and 1.0 mL is the amount most widely utilized [17,19,21,23,36,[75][76][77]. Some authors suggest rinsing the needle several times and collecting the full amount of washout fluid in a single tube.…”
Section: Pre-analytical Factors: Collection Preparation E Managementmentioning
confidence: 99%
“…Cytology findings of the LNs reviewed by experienced pathologists were categorized as non-diagnostic, benign and metastatic papillary thyroid carcinoma (PTC; suspicious malignancy, malignancy) (5,10,19,20,21).…”
Section: Fnac and Final Pathologymentioning
confidence: 99%