2016
DOI: 10.1088/0031-8949/91/7/074009
|View full text |Cite
|
Sign up to set email alerts
|

Diagnostics of low-pressure hydrogen discharge created in a 13.56 MHz RF plasma reactor

Abstract: A 13.56 MHz RF discharge in hydrogen was studied within the pressure range of 1-10 Pa, and at power range of 400 -1000 W. The electron energy distribution function and electron density were measured by a Langmuir probe. The gas temperature was determined by the Fulcher-α system in pure H2, and by the second positive system of nitrogen using N2 as the probing gas. The gas temperature was constant and equal to 450 ± 50 K in the Capacitively Coupled Plasma mode (CCP), and it was increasing with pressure and power… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
7
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(8 citation statements)
references
References 99 publications
1
7
0
Order By: Relevance
“…At the moment of the calibration, an alumina sample was installed in the chamber instead of the quartz sample. The sample material could affect the atomic density when compared to the full quartz situation, but the order of magnitude obtained here are still comparable to previous measurements realised in steady state plasma [5] since the sample surface was relatively small compared to surface area of the rest of the chamber walls. The absolute atom density at a time delay of 0.05 ms was (9 ± 1) × 10 19 m −3 .…”
Section: Absolute Density Calibrationsupporting
confidence: 83%
See 3 more Smart Citations
“…At the moment of the calibration, an alumina sample was installed in the chamber instead of the quartz sample. The sample material could affect the atomic density when compared to the full quartz situation, but the order of magnitude obtained here are still comparable to previous measurements realised in steady state plasma [5] since the sample surface was relatively small compared to surface area of the rest of the chamber walls. The absolute atom density at a time delay of 0.05 ms was (9 ± 1) × 10 19 m −3 .…”
Section: Absolute Density Calibrationsupporting
confidence: 83%
“…The absolute atom density at a time delay of 0.05 ms was (9 ± 1) • 10 19 m −3 . The absolute atom density in this experimental set-up and at the same pressure and RF power but in steady state was also determined by Ar actinometry with H β line in H 2 + 5% Ar plasma using a Pyrex tube instead of a quartz one (Figure 14 of reference [5]). The result was ∼ 2.5 • 10 20 m −3 which compares quite well in term of order of magnitude to the present experiment given the slight differences between the experimental conditions (Pyrex tube instead of quartz tube, quartz sample instead of alumina sample, introduction of 5% argon, etc).…”
Section: Absolute Density Calibrationmentioning
confidence: 99%
See 2 more Smart Citations
“…• 325 K is the wall temperature of the reactor, and in the isothermal case it is assumed that all temperature gradients are zero. • 450 K corresponds to the operating conditions of previous experiments [53,65,66]. • 600 K corresponds to the configuration of previously undertaken simulations with an isothermal neutral gas [26].…”
Section: Atomic Hydrogen Densitiesmentioning
confidence: 99%