2016
DOI: 10.1016/j.ajic.2016.02.009
|View full text |Cite
|
Sign up to set email alerts
|

Dialysis Event Surveillance Report: National Healthcare Safety Network data summary, January 2007 through April 2011

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
12
4
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
8
2

Relationship

1
9

Authors

Journals

citations
Cited by 19 publications
(20 citation statements)
references
References 6 publications
3
12
4
1
Order By: Relevance
“…Dialysis events surveillance can help identify patient-specific and device-related risks, and promote intervention practices to reduce infections and complications. There were a limited number of studies published on the dialysis events to date, 16,[21][22][23][24][25] and especially less of prospective studies came from outside the United States. 22,23 Therefore, this prospective multicenter study was designed for 16,23 Two important issues should be noted when results of this study were compared with studies from other countries.…”
Section: Discussionmentioning
confidence: 99%
“…Dialysis events surveillance can help identify patient-specific and device-related risks, and promote intervention practices to reduce infections and complications. There were a limited number of studies published on the dialysis events to date, 16,[21][22][23][24][25] and especially less of prospective studies came from outside the United States. 22,23 Therefore, this prospective multicenter study was designed for 16,23 Two important issues should be noted when results of this study were compared with studies from other countries.…”
Section: Discussionmentioning
confidence: 99%
“…el año 2014 existieron 160.971 eventos adversos asociados al procedimiento de hemodiálisis ambulatoria (29) . Esta institución (NHSN), mediante evaluación retrospectiva de reportes de EA, comunica la ocurrencia de 24.092 eventos adversos en el periodo 2007-2011, identificándolos como: necesidad de hospitalización, inicio de terapia antibiótica e infección del acceso vascular (30) . Matarán Robles et al, mediante vigilancia pasiva, reportaron la ocurrencia de 141,96 eventos adversos por cada 1.000 procedimientos en un estudio realizado en un periodo de un año calendario (31) .…”
Section: Discussionunclassified
“…In for approximately 25% of isolates in bloodstream infections (130,131). A study found that the prevalence and incidence of colonization with MDR-GNB were greater than those of colonization with MRSA or VRE in an outpatient hemodialysis facility in the United States (132).…”
Section: Mdros In Dialysis and Non-dialysis Ckd Patientsmentioning
confidence: 99%