1975
DOI: 10.3109/00365517509095808
|View full text |Cite
|
Sign up to set email alerts
|

Diameter of the Afferent Arteriole in the Dog Kidney Estimated by the Microsphere Method

Abstract: Microspheres with diameters of from 10 to 30 mum were injected into the renal arteries of three anesthetized dogs. The six kidneys were studied by light microscopy. The diameters of the spheres trapped in the afferent arterioles and of all spheres recovered in the kidneys were recorded. On the basis of the distribution of diameters in these two populations of spheres, the average diameter of the afferent arteriole and the distribution of the afferent arteriolar diameters were estimated. The average diameter of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

3
27
1

Year Published

1978
1978
1989
1989

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(31 citation statements)
references
References 11 publications
3
27
1
Order By: Relevance
“…The discrepancy between the estimated mean diameter values for the afferent arteriole presented here and that derived from the diameter of the microsphere trapped in the afferent arterioles 4 may be explained by the presence of some small nonoccluding microspheres trapped behind larger ones. The present regression model is not as sensitive to this special effect as the method published earlier which gave slightly lower diameter values.…”
Section: Figure 3 Relationship Between Microsphere Diameter and Ratiocontrasting
confidence: 80%
See 3 more Smart Citations
“…The discrepancy between the estimated mean diameter values for the afferent arteriole presented here and that derived from the diameter of the microsphere trapped in the afferent arterioles 4 may be explained by the presence of some small nonoccluding microspheres trapped behind larger ones. The present regression model is not as sensitive to this special effect as the method published earlier which gave slightly lower diameter values.…”
Section: Figure 3 Relationship Between Microsphere Diameter and Ratiocontrasting
confidence: 80%
“…To account for possible axial streaming effects in addition to pure geometrical exclusion, f(p,r) may be chosen somewhere between the geometrical exclusion factor and Ferry's correction factor, 5 ' 7 tentatively f(p,r) = 1 -p/r) y ; 0 < p < r ); otherwise (4) where y has to be determined; y = 0 corresponds to the case with pure geometrical exclusion.…”
Section: Juxtamedullary Cortex (Jmc)mentioning
confidence: 99%
See 2 more Smart Citations
“…Thus, preglomerular vasoconstriction is still a viable hemodynamic explanation for the decreased GFR of acute renal failure. To test this hypothesis, we measured afferent arteriolar diameter in glycerol-induced acute renal failure, using a recently developed microsphere method (Chenitz et al, 1976;Ishikawa and Hollenberg, 1977;Ofstad et al, 1975). …”
mentioning
confidence: 99%