1970
DOI: 10.1039/tf9706601720
|View full text |Cite
|
Sign up to set email alerts
|

Dielectric behaviour of adsorbed water films on the ?-Fe2O3 surface

Abstract: The electrical capacitance at 70 c/s to 300 kc/s of physically adsorbed water on o(-Fe203 is constant within the monolayer volume but rises abruptly at low frequencies with the onset of a second layer. This behaviour suggests that the first layer of physically adsorbed water is immobile, but that succeeding layers are mobile. Characteristic relaxation frequencies obtained from Cole-Cole arc plots increase smoothly from 10 c/s to 10 kc/s at B.E.T. coverages of three or higher. Three intermediate stages in the b… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
48
0

Year Published

1988
1988
2016
2016

Publication Types

Select...
8
1
1

Relationship

1
9

Authors

Journals

citations
Cited by 109 publications
(48 citation statements)
references
References 1 publication
0
48
0
Order By: Relevance
“…activation energies of various relaxation processes decreased with increasing surface coverage in clay materials [162] and polymer composites [165] but increased in Fe 2 O 3 [156], Ag 2 O [168], silica [170,176], calcium-silicate-hydrate [157,158] and ovalbumine adsorbents [166,171].…”
Section: Dependence Of the Activation Energy On Water Adsorptionmentioning
confidence: 99%
“…activation energies of various relaxation processes decreased with increasing surface coverage in clay materials [162] and polymer composites [165] but increased in Fe 2 O 3 [156], Ag 2 O [168], silica [170,176], calcium-silicate-hydrate [157,158] and ovalbumine adsorbents [166,171].…”
Section: Dependence Of the Activation Energy On Water Adsorptionmentioning
confidence: 99%
“…The adsorption of these compounds is influenced by the electronic structure of the inhibiting molecules [9,10] and also by the steric factors, aromaticity, electron density at the donor atoms, and the presence of functional groups [11][12][13][14].…”
Section: Introductionmentioning
confidence: 99%
“…For these applications HCl is considered to be superior and more economical than H 2 SO 4 [3]. A number of compounds containing nitrogen and/or sulphur have been studied as corrosion inhibitors and have shown excellent performance [4][5][6][7][8][9][10][11][12][13][14]. However, the environmental impact of these inhibitors has been considered in the recent decades due to their toxic effects on aquatic and possibly animal life [15].…”
Section: Introductionmentioning
confidence: 99%