2016
DOI: 10.1016/j.biosystemseng.2016.03.002
|View full text |Cite
|
Sign up to set email alerts
|

Dielectric properties of peanut kernels associated with microwave and radio frequency drying

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

9
37
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 90 publications
(46 citation statements)
references
References 33 publications
9
37
0
Order By: Relevance
“…The signal analyzers used for dielectric property measurements include LCR [inductance (L), capacitance (C), resistance (R)] meters, impedance analyzers, and spectrum/ (Izadifar & Baik 2008, Ozturk et al 2016 or an impedance analyzer (20 Hz-3 GHz) (Boreddy & Subbiah 2016, Jeong & Kang 2014, Llave et al 2014, Wang et al 2003b provide accurate results. Spectrum/network/vector analyzers work well for high frequencies (30 kHz-8.5 GHz) (Zhang et al 2016, Zhu et al 2014) but could also be used to measure at RFs with lower accuracy especially for low-moisture food products. The dielectric properties of a food material, in general, change with its composition and temperature.…”
Section: Measuring Of Dielectric Propertiesmentioning
confidence: 99%
“…The signal analyzers used for dielectric property measurements include LCR [inductance (L), capacitance (C), resistance (R)] meters, impedance analyzers, and spectrum/ (Izadifar & Baik 2008, Ozturk et al 2016 or an impedance analyzer (20 Hz-3 GHz) (Boreddy & Subbiah 2016, Jeong & Kang 2014, Llave et al 2014, Wang et al 2003b provide accurate results. Spectrum/network/vector analyzers work well for high frequencies (30 kHz-8.5 GHz) (Zhang et al 2016, Zhu et al 2014) but could also be used to measure at RFs with lower accuracy especially for low-moisture food products. The dielectric properties of a food material, in general, change with its composition and temperature.…”
Section: Measuring Of Dielectric Propertiesmentioning
confidence: 99%
“…Li et al [7] also found that MVD mushroom slices were of higher quality in terms of their rehydration ratio, colour, and Vc retention rate, than samples obtained by hot air drying or vacuum drying; further, these authors reported that although the quality of MVD samples was similar to that of FD samples, the drying time for MVD was only 4.2% that of the total FD time. Pei et al [8] studied freeze-drying combined with microwave vacuum drying (FD+MVD) of A. bisporus slices and found that this method reduced the drying time by 35.63% in comparison with FD, and enabled the production of high-quality products. In addition, the drying effects and efficiency of the three different sublimation drying methods for A. bisporus, namely FD, microwave freeze drying (MFD) and atmospheric freeze drying (AFD), were compared by Xu et al [9] The results showed that, compared with FD and AFD, MFD enabled relatively acceptable quality and drying efficiency.…”
Section: Introductionmentioning
confidence: 99%
“….27 mm at 2450 MHz. The decreased d p as frequency increased was also reported on other foods and agricultural products, e.g., fruits (Lombardo et al, 2015), peanut kernels (Zhang et al, 2016) and milk (Muñoz et al, 2018). Since d p was influenced by the frequency and solids-not-fat content greatly, choosing an appropriate thickness is very important to offer accurate measurement results when detecting solidsnot-fat content in skim milk.…”
Section: Regression Between Permittivities and Solids-not-fat Contentmentioning
confidence: 70%
“…When the solids‐not‐fat content increased from 10.04% to 14.68%, d p decreased from 81.53 to 66.61 mm at 27.12 MHz, from 70.22 to 56.44 mm at 40.68 MHz, from 30.86 to 23.28 mm at 915 MHz and from 11.89 to 10.27 mm at 2450 MHz. The decreased d p as frequency increased was also reported on other foods and agricultural products, e.g., fruits (Lombardo et al ., ), peanut kernels (Zhang et al ., ) and milk (Muñoz et al ., ). Since d p was influenced by the frequency and solids‐not‐fat content greatly, choosing an appropriate thickness is very important to offer accurate measurement results when detecting solids‐not‐fat content in skim milk.…”
Section: Resultsmentioning
confidence: 99%