Abstract: Background Electrical pulse stimulations have been applied in brain for treating certain diseases such as movement disorders. High-frequency stimulations (HFS) of biphasic pulses have been used in clinic stimulations, such as deep brain stimulation (DBS), to minimize the risk of tissue damages caused by the electrical stimulations. However, HFS sequences of monophasic pulses have often been used in animal experiments for studying neuronal responses to the stimulations. It is not clear yet what … Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
2
2
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 35 publications
0
3
0
Order By: Relevance
“…The therapeutic efficacy of modulating waveform asymmetry may then require longer duration trains of stimulation, such as explored in the present study, or higher amplitudes within the safety limits. It should be noted that long-lasting depression of neural activity followed stimulation (figures 1-3), reminiscent of stimulation induced depression of neural excitability [79][80][81]. This may lead to reduced perceptual sensitivity to ICMS when delivered with short latency between stimulation [76].…”
Section: Implications For Neural Technologymentioning
confidence: 99%
“…The therapeutic efficacy of modulating waveform asymmetry may then require longer duration trains of stimulation, such as explored in the present study, or higher amplitudes within the safety limits. It should be noted that long-lasting depression of neural activity followed stimulation (figures 1-3), reminiscent of stimulation induced depression of neural excitability [79][80][81]. This may lead to reduced perceptual sensitivity to ICMS when delivered with short latency between stimulation [76].…”
Section: Implications For Neural Technologymentioning
confidence: 99%
“…The effect of commercial DBS system heavily depends on the parameters of the applied stimulation pulses, including the waveform, pulse width, frequency, and amplitude 41 , 42 . For the waveform, the monophasic pulses may generate toxic products by electrochemical reactions 43 , while charge-balanced biphasic pulses may prevent irreversible chemical reactions in the brain tissue around the electrode contacts 44 , 45 and are generally used in clinical DBS for safety. For the stimulation frequency, in comparison with low-frequency stimulation 46 , 47 , the high-frequency (>100 Hz) stimulation is an established medical treatment for PD motor symptoms 48 .…”
Section: Methodsmentioning
confidence: 99%
“…However, It should be noted that long-lasting depression of neural activity followed stimulation (Fig. 1-3), reminiscent of stimulation induced depression of neural excitability (SIDNE) (79)(80)(81). This may lead to reduced perceptual sensitivity to ICMS when delivered with short latency between stimulation(77).…”
Section: Implications For Neural Technologymentioning
confidence: 99%