2017
DOI: 10.15199/48.2017.10.26
|View full text |Cite
|
Sign up to set email alerts
|

Differential protection of three and four parallel lines of idling current control

Abstract: Algorithms of operation of three or four parallel lines protections, based on the difference between the control currents in the corresponding phases and current in comparison with their idling current are proposed. The implementing of protections of three parallel lines on logic elements is given. The work is considered in different modes. It is shown that when the three lines of action of cascade zone do not exceed the line length of 0.08, while the four-0.06. Streszczenie. Opisano algorytm umożliwiający zab… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
1
0
4

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
5

Relationship

0
10

Authors

Journals

citations
Cited by 15 publications
(5 citation statements)
references
References 2 publications
0
1
0
4
Order By: Relevance
“…Дәстүр бойынша электр қондырғыларын қысқа тұйықталудан қорғанысы, соның ішінде соңғы онжылдықтардағы әзірлемелер [1][2][3][4][5], ток туралы ақпаратты металсыйымдылықты және көлемді ток трансформаторларынан алады. Белгілі [6,7] бойынша, қазіргі уақытта осы ток түрлендіргіштерін пайдаланбай осындай қорғаныстарды құру міндеті өзекті болып табылады.…”
Section: кіріспеunclassified
“…Дәстүр бойынша электр қондырғыларын қысқа тұйықталудан қорғанысы, соның ішінде соңғы онжылдықтардағы әзірлемелер [1][2][3][4][5], ток туралы ақпаратты металсыйымдылықты және көлемді ток трансформаторларынан алады. Белгілі [6,7] бойынша, қазіргі уақытта осы ток түрлендіргіштерін пайдаланбай осындай қорғаныстарды құру міндеті өзекті болып табылады.…”
Section: кіріспеunclassified
“…Keywords: relay protection, reed switch, microprocessor, surge current, time measurement, magnetic field, transient particular current transformers, are necessary to obtain information about the primary current (magnitude, phase, etc.) [2]. However, current transformers are prone to saturation [3], which can cause difficulties in the implementation of protection functions [4].…”
Section: A Study Of the Functioning Of Reed Switches Under The Influence Of A Magnetic Field Created By A Current In A Conductor In A Tramentioning
confidence: 99%
“…Для защиты параллельных линий электропередачи традиционно предлагается использовать поперечную дифференциальную токовую направленную защиту, обладающую различными недостатками [1]. Способы устранения большинства из них изложены в [2,3]. При этом все они основаны на получении информации о токах в линиях от трансформаторов тока, из-за недостатков которых на сессиях СИГРЭ [4,5], а также в высокорейтинговых журналах [6], неоднократно поднимался вопрос о необходимости построения защит без их использования.…”
Section: Introductionunclassified