2021
DOI: 10.1016/j.talanta.2020.121594
|View full text |Cite
|
Sign up to set email alerts
|

Differential pulse voltammetric determination of homovanillic acid as a tumor biomarker in human urine after hollow fiber-based liquid-phase microextraction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(9 citation statements)
references
References 58 publications
0
9
0
Order By: Relevance
“…The Si-CD@CdTe@CMIP had a broader determination range compared with other methods. The LOD of Si-CD@CdTe@CMIP was lower than that of trace analysis in previous studies. , Importantly, the Si-CD@CdTe@CMIP method achieved the lower detection limit with a lower sample consumption of 18 μL, which proved that the Si-CD@CdTe@CMIP can be used for detection of trace samples.…”
Section: Resultsmentioning
confidence: 70%
See 1 more Smart Citation
“…The Si-CD@CdTe@CMIP had a broader determination range compared with other methods. The LOD of Si-CD@CdTe@CMIP was lower than that of trace analysis in previous studies. , Importantly, the Si-CD@CdTe@CMIP method achieved the lower detection limit with a lower sample consumption of 18 μL, which proved that the Si-CD@CdTe@CMIP can be used for detection of trace samples.…”
Section: Resultsmentioning
confidence: 70%
“…Studies showed that the level of HVA decreases while the concentration of Al 3+ increases in PD patients. Thus, simultaneous detection of HVA and Al 3+ is of great significance for the early diagnosis and monitoring of PD. Currently, the detection methods of HVA or Al 3+ included enzymatic immunological assays (EIA), liquid chromatography (LC), gas chromatography–mass spectrometry (GC–MS), and high-performance liquid chromatography (HPLC). However, these methods have some shortcomings such as the lack of specificity, poor sensitivity, large reagent consumption, and individual determination …”
Section: Introductionmentioning
confidence: 99%
“…Troeger's/SPE PB pH 7.0 DPV 2.2 [49] L-leucine modified Sol-Gel-Carbon electrode PB pH 7.4 DPV 0.1 [50] Cu/GCE PB pH 7.2 SWV 1.0×10 −2 [51] Boron doped diamond electrode 0.1 mol L -1 1 HCl DPV 0.4 [52] Metal-doped zirconia /CPE BR pH 4 DPV 0.273 This work…”
Section: Electrochemical Application: Detection Of Cancer Biomarkersmentioning
confidence: 99%
“…The presence of vanillymandelic acid, produced almost exclusively in the human liver, present in human urea indicates the presence of tumor cells such as PCC, paraganglioma or neuroblastoma [ 16 ]. Since the 1970s, VMA has also been used as a biomarker of metabolic disorders such as dopamine excretion disorders, as well as neurological disorders such as autism, post-traumatic stress disorder, Parkinson’s disease or depression [ 17 ]. Mandelic acid derivatives are still poorly described in the literature.…”
Section: Introductionmentioning
confidence: 99%