2021
DOI: 10.1101/2021.12.15.472712
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Differing Associations between Optic Nerve Head Strains and Visual Field Loss in Normal- and High-Tension Glaucoma Subjects

Abstract: PurposeTo study the associations between optic nerve head (ONH) strains under intraocular pressure (IOP) elevation with retinal sensitivity in glaucoma subjects.DesignClinic based cross-sectional study.Participants229 subjects with primary open angle glaucoma (subdivided into 115 high tension glaucoma (HTG) subjects and 114 normal tension glaucoma (NTG) subjects).MethodsFor one eye of each subject, we imaged the ONH using spectral-domain optical coherence tomography (OCT) under the following conditions: (1) pr… Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(9 citation statements)
references
References 62 publications
(46 reference statements)
0
9
0
Order By: Relevance
“…The errors observed here could arise from various sources such as OCT registration errors (intrinsic to the OCT machine), rotation of subjects' head during OCT acquisition, OCT speckle noise and IOP fluctuations from ocular pulsations, 73 all of which were difficult to control. However, displacement error magnitudes were still lower than the OCT voxel resolution; 20 thus, these errors should not have significantly affected our observed trends.…”
Section: Discussionmentioning
confidence: 74%
See 4 more Smart Citations
“…The errors observed here could arise from various sources such as OCT registration errors (intrinsic to the OCT machine), rotation of subjects' head during OCT acquisition, OCT speckle noise and IOP fluctuations from ocular pulsations, 73 all of which were difficult to control. However, displacement error magnitudes were still lower than the OCT voxel resolution; 20 thus, these errors should not have significantly affected our observed trends.…”
Section: Discussionmentioning
confidence: 74%
“…For each eye in the primary gaze position, we applied a constant force of 0.65 N to the temporal side of the lower eyelid using an opthalmodynamometer (ODM), as per an established protocol. 20, 21, 34 The force was applied for approximately 2 to 3 minutes throughout the OCT scan duration and varied for no more than one minute across subject. This force raised IOP to about 35 mmHg and was maintained constant.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations