2009
DOI: 10.1016/j.actbio.2009.03.009
|View full text |Cite
|
Sign up to set email alerts
|

Diffusion of soluble factors through degradable polymer nerve guides: Controlling manufacturing parameters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
136
0
2

Year Published

2010
2010
2023
2023

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 101 publications
(139 citation statements)
references
References 22 publications
1
136
0
2
Order By: Relevance
“…In addition, the pore size in the cross-section region of the PCL scaffolds was around 10 mm ( Fig. 1(b)), and the thickness of the scaffold 600 mm which would be suitable for nerve conduits reported by Kokai et al [28].…”
Section: Morphology and Porosity Of Pcl Scaffoldmentioning
confidence: 93%
“…In addition, the pore size in the cross-section region of the PCL scaffolds was around 10 mm ( Fig. 1(b)), and the thickness of the scaffold 600 mm which would be suitable for nerve conduits reported by Kokai et al [28].…”
Section: Morphology and Porosity Of Pcl Scaffoldmentioning
confidence: 93%
“…Additionally, for materials that are not as apparently beneficial as E10-0.5(1K) on nerve regeneration, porosity may be more of a driving factor in successful regeneration, allowing for greater diffusion of nutrients, growth factors, and cells into the inner lumen and may help to develop and sustain a viable fibrin matrix across the entire length of the nerve gap. 77 When E10-0.5(1K) conduits were compared against a NP-PE conduit, animals treated with E10-0.5(1K) conduits statistically performed better. Transection of the femoral nerve leads to atrophy of the quadriceps muscle and prevents proper extension, which can be visualized during individual steps of the mouse taken during the normal walking cycle.…”
mentioning
confidence: 99%
“…The dry weight of each guide was recorded between successive salt leaching periods. Previous work has indicated that in an 80% porous nerve guide, very few closed pores exist from which remaining salt crystals could not dissolve [23].…”
Section: Evaluation Of Sodium Chloride Leaching From Nerve Guide Wallsmentioning
confidence: 99%
“…PCL nerve guides were fabricated using a modification of previously reported methods [23]. Glass capillary mandrels 1.5 mm in diameter were coated with a 17% w/v% aqueous solution of poly(vinyl alcohol) (PVA), air dried and then immersed into the polymer slurry (as described above) creating NaCl/PCL mandrel coatings.…”
Section: Nerve Guidesmentioning
confidence: 99%