Digital Determination and Recording of Edentulous Maxillomandibular Relationship Using a Jaw Movement Tracking System

Abstract: To establish a direct digital method for determining and recording edentulous maxillomandibular relationship using a custom-made jaw movement tracking system and evaluate its accuracy. Materials and methods: A novel jaw tracking system was used to record the trajectory of habitual opening-closing jaw movement, and mandibular rest position (MRP) in 10 edentulous patients. 3D surface scanning was performed on the conventional maxillomandibular impressions and facial structures of patients in MRP. The multisource… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(9 citation statements)
references
References 28 publications
0
9
0
Order By: Relevance
“…The assessment results for risk of bias for different study designs are presented in Supplementary Tables 2 to 4, available online. Seven randomized controlled trials 13,[26][27][28][29][30][31] had fair to good quality, but 13 cohort studies [1][2][3]20,[32][33][34][35][36][37][38][39][40] and 3 other studies 16,41,42 were considered poor quality. The remaining studies were also considered fair to good quality.…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…The assessment results for risk of bias for different study designs are presented in Supplementary Tables 2 to 4, available online. Seven randomized controlled trials 13,[26][27][28][29][30][31] had fair to good quality, but 13 cohort studies [1][2][3]20,[32][33][34][35][36][37][38][39][40] and 3 other studies 16,41,42 were considered poor quality. The remaining studies were also considered fair to good quality.…”
Section: Resultsmentioning
confidence: 99%
“…Among 39 included studies, 7 studies 33,37,38,40,[43][44][45] assessed denture bases, 2 studies 8,36 assessed trial dentures, and 26 studies [1][2][3]5,6,[13][14][15][16][17][18][19][20][26][27][28][29][30][31]41,42,[46][47][48][49][50] investigated definitive complete dentures, including 2 studies 26,29 with implant overdentures (IOD). Four studies 32,34,35,39 assessed digital scans of impression or edentulous jaws for…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations