2022
DOI: 10.1107/s160057672200677x
|View full text |Cite
|
Sign up to set email alerts
|

Digitization of imaging plates from Guinier powder X-ray diffraction cameras

Abstract: A Guinier camera equipped with an imaging plate is used to investigate and eliminate the sources of instrumental errors affecting the quality of the obtained scanned Guinier data. A program with a graphical user interface is presented which converts the data of the scanned images into different standard file formats for powder X-ray patterns containing intensities, their standard deviations and the diffraction angles. The program also allows for manual and automatic correction of the 2θ scale against a known r… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
2

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 43 publications
0
4
0
1
Order By: Relevance
“…The diffraction images were recorded on a BaFX:Eu-based imaging plate (IP) film. [34] During the measurements, the samples were sliding sideways in the X-ray beam. The X-ray exposed imaging plate was scanned using Typhoon FLA 7000 5/21 scanner (GE Company, USA).…”
Section: /21mentioning
confidence: 99%
“…The diffraction images were recorded on a BaFX:Eu-based imaging plate (IP) film. [34] During the measurements, the samples were sliding sideways in the X-ray beam. The X-ray exposed imaging plate was scanned using Typhoon FLA 7000 5/21 scanner (GE Company, USA).…”
Section: /21mentioning
confidence: 99%
“…BaFX:Eu-based imaging plate (IP) film. [34] During the measurements, the samples were sliding sideways in the X-ray beam. The X-ray exposed imaging plate was scanned using Typhoon FLA 7000 scanner (GE Company, USA).…”
Section: /22mentioning
confidence: 99%
“…All the recorded diffraction images were digitized using the IPreader software and the averaging of 64 scans for BET30 and 16 scans for the rest of the samples was done by a gnuplot tcl-script. [34] Rietveld refinement [35] and other types of line shape analyses were performed using TOPAS-Academic V7 software package. [36]…”
Section: /22mentioning
confidence: 99%
“…A silicon dioxide standard (Quarzwerke Dörentrup “alpha SiO 2 quartz”, a finely ground standard for XRD, a = 4.9136 Å, c = 5.4054 Å) was used as a reference sample. IPreader software 43 was used for data extraction and TOPAS academic software package v.4 (ref. 44) for Rietveld refinement and quantitative phase analysis of the sample.…”
Section: Experimental Partmentioning
confidence: 99%