Dimensional accuracy of 3D printed models using different voxel size CBCT (Comparative Experimental Study)
Khaled El Mahdy,
Mona Abo Elfotouh,
Fatma ElBadawy
Abstract:To evaluate the influence of different imaging protocols (voxel sizes) of CBCT on linear measurements accuracy of different printed 3d models. Methods and Material: Ten intact casts with complete dentition were selected and anonymously numbered from 1-10. Casts were prepared with round bur size 2 at certain specific points to be used as fixed measurement limits. Casts were then scanned with the same CBCT machine using two voxel size protocols (0.125mm and 0.3mm). Each scan was then imported into ondemand3d app… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.