2013
DOI: 10.4012/dmj.2012-159
|View full text |Cite
|
Sign up to set email alerts
|

Dimensional changes in stone casts resulting from long-term immersion of addition-type silicone rubber impressions in disinfectant solutions

Abstract: There is a concern that long-term immersion of impressions in disinfectant solutions may cause changes in the dimensions of the resulting stone casts. This study investigated the dimensional changes in stone casts resulting from immersion of five brands of addition-type silicone rubber impressions in disinfectant solutions for 30 min and 24 h. Impressions of a master cast designed to simulate an abutment tooth were immersed in 2% glutaraldehyde and 0.55% ortho-phthalaldehyde. The diameter of the stone cast was… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
24
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(24 citation statements)
references
References 10 publications
0
24
0
Order By: Relevance
“…It has been reported that the accuracy of hydrophilic additiontype silicone rubber impression materials is adversely affected by 18-h immersion in 2% glutaraldehyde solution, and shows decreases in the mesiodistal and buccolingual dimensions 5) . A previous study 8) has also reported that 24-h immersion of low-viscosity additiontype silicone rubber impression materials in disinfectant solutions caused a significant decrease in the dimensions of the resulting stone models. However, the effects varied according to the brand of impression material and the disinfectant solution employed [5][6][7][8] .…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…It has been reported that the accuracy of hydrophilic additiontype silicone rubber impression materials is adversely affected by 18-h immersion in 2% glutaraldehyde solution, and shows decreases in the mesiodistal and buccolingual dimensions 5) . A previous study 8) has also reported that 24-h immersion of low-viscosity additiontype silicone rubber impression materials in disinfectant solutions caused a significant decrease in the dimensions of the resulting stone models. However, the effects varied according to the brand of impression material and the disinfectant solution employed [5][6][7][8] .…”
Section: Discussionmentioning
confidence: 99%
“…A previous study 8) has also reported that 24-h immersion of low-viscosity additiontype silicone rubber impression materials in disinfectant solutions caused a significant decrease in the dimensions of the resulting stone models. However, the effects varied according to the brand of impression material and the disinfectant solution employed [5][6][7][8] . Therefore, detailed investigation of the effects of long-term immersion of hydrophilic addition-type silicone rubber impression materials might help to devise methods of long-term disinfection that are clinically acceptable.…”