Abstract:The inefficiency in controlling the slurry/froth interface level of a scavenger column flotation stage was severely impairing the process performance of an iron mining company, increasing the iron content in the tailings to levels above 20% and, consequently, not meeting the company's iron recovery and pellet feed production targets. Based on mass balance and process data, hydraulic calculations were performed and showed that the installed 6.0" (15.24cm) diameter barometric leg tubes and the control system val… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.