2005
DOI: 10.1016/j.ics.2005.03.153
|View full text |Cite
|
Sign up to set email alerts
|

Diminution index: A novel 3D feature for pulmonary nodule detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2008
2008
2016
2016

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 3 publications
0
5
0
Order By: Relevance
“…After this analysis, only 38 articles [24,4,18,22,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40,41,42,43,44,45,46,47,48,49,50,51,52,53,54,55,56,57,58] were identified as 3D automated algorithms to segment lung nodules in CT images, the target of this work.…”
Section: Work Selection Criteriamentioning
confidence: 99%
See 2 more Smart Citations
“…After this analysis, only 38 articles [24,4,18,22,25,26,27,28,29,30,31,32,33,34,35,36,37,38,39,40,41,42,43,44,45,46,47,48,49,50,51,52,53,54,55,56,57,58] were identified as 3D automated algorithms to segment lung nodules in CT images, the target of this work.…”
Section: Work Selection Criteriamentioning
confidence: 99%
“…This stage is important since the lungs also contain several structures that can be confused with nodules. Just eight of the selected works for this review indicate the preprocessing techniques used: linear interpolation [26,29,46], median filter [27,28], morphological Hat operation [28], Gaussian filter [32,52] and weighted-sum filter [51].…”
Section: Preprocessingmentioning
confidence: 99%
See 1 more Smart Citation
“…The diminution index of the nodule candidate is then defi ned to take the value given by one minus the ratio of the volume of the distal part to that of the proximal part. 8 As is obvious from this defi nition, the diminution index provides a measure that is independent of the absolute size of the nodule candidate. Thus, the following characteristics of the diminution index, which are highly suitable for CAD of lung nodules on CT, hold for nodule candidates of any size: The values of the diminution index are close to 1 for nodule candidates representing isolated nodules and generally around 0 or lower for nodule candidates caused by blood vessels; as compared with these two cases, the values of the diminution index are in an intermediate range for nodule candidates representing juxtavascular nodules.…”
Section: Patients and Ct Image Databasementioning
confidence: 99%
“…The resultant summary measure of the 3D analysis of nodule candidates and their surroundings, called the diminution index, has shown promising capability in the classifi cation of nodule candidates. 8 We have been developing a CAD system for lung nodules on MDCT whose scheme for nodule detection integrates the above 3D analysis of nodule candidates and their surroundings with the preceding identifi cation of nodule candidates using deformable ellipsoid models. The purpose of this study was to conduct a preliminary evaluation of the CAD system.…”
Section: Introductionmentioning
confidence: 99%