2012
DOI: 10.1002/rcm.6116
|View full text |Cite
|
Sign up to set email alerts
|

Direct detection of additives and degradation products from polymers by liquid extraction surface analysis employing chip‐based nanospray mass spectrometry

Abstract: For the first time, in situ detection of analytes from a thermoset polymer coating was accomplished without any sample preparation, providing advantages over traditional extraction-analysis approaches and some contemporary ambient MS methods. Detection of HALS and polymer degradation products such as melamine provides insight into the mechanisms by which degradation occurs and suggests LESA-MS is a powerful new tool for polymer analysis.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
26
0

Year Published

2012
2012
2016
2016

Publication Types

Select...
4
4

Relationship

2
6

Authors

Journals

citations
Cited by 32 publications
(27 citation statements)
references
References 26 publications
0
26
0
Order By: Relevance
“…Alkoxyamines are readily detected as protonated or alkali metal adduct ions by electrospray ionisation (ESI), [48] matrix assisted laser desorption ionisation (MALDI), [70,71] liquid extraction surface analysis (LESA), [72] or desorption electrospray ionisation (DESI). [73] However, in the absence of another basic moiety, protonation of an alkoxyamine nitrogen raises the O-C BDE by over 100 kJ mol -1 .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Alkoxyamines are readily detected as protonated or alkali metal adduct ions by electrospray ionisation (ESI), [48] matrix assisted laser desorption ionisation (MALDI), [70,71] liquid extraction surface analysis (LESA), [72] or desorption electrospray ionisation (DESI). [73] However, in the absence of another basic moiety, protonation of an alkoxyamine nitrogen raises the O-C BDE by over 100 kJ mol -1 .…”
Section: Resultsmentioning
confidence: 99%
“…The former dissociation is consistent with previous reports on the charge-directed dissociation of substituted piperidines. [72] In the absence of the desired charge-remote dissociation of the alkoxyamine moiety, an alternative strategy was sought. Only limited examples in the literature describe the tandem mass spectrometric analysis of alkoxyamines upon negative ion electrospray ionisation.…”
Section: Resultsmentioning
confidence: 99%
“…Several authors have reported good results after using this high-sensitive instrument, allowing the simultaneous identification and quantification of the proteins of interest (Grobosch et al, 2012;Janeckova et al, 2012;Lazartigues et al, 2011;Li et al, 2011;Paine et al, 2012;Rust et al, 2012;Wu et al, 2011).…”
Section: Ab Sciex Qtrap R 5500 Lc/ms/ms Systemmentioning
confidence: 99%
“…Nowadays there are various analytical tools for analyzing polymer additives. A direct analytical method for the detection of several HALS in solid polymer samples using liquid extraction surface analysis mass spectrometry (LESA-MS) was reported by Paine et al [16,17]. Although this method provides a simple and fast analysis, it does not readily allow absolute quantitation.…”
Section: Introductionmentioning
confidence: 99%