2003
DOI: 10.1039/b302633g
|View full text |Cite
|
Sign up to set email alerts
|

Direct determination of bismuth in urine samples by electrothermal atomic absorption spectrometry: study of chemical modifiers

Abstract: In this work the performance of some chemical modifiers (no modifier, Pd 1 Mg, Ir in solution, Ru, Ir or Zr independently as permanent modifier and Ir 1 Rh permanent) was investigated for the direct determination of Bi in human urine by electrothermal atomic absorption spectrometry (ETAAS). The urine samples were diluted directly in the autosampler cups with one-fold dilution with nitric acid 1% v/v. The obtaining of the permanent modifiers (500 mg of iridium, ruthenium and zirconium independently and 250 mg o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2004
2004
2023
2023

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 20 publications
(9 citation statements)
references
References 19 publications
0
9
0
Order By: Relevance
“…For the determination of bismuth in urine [51], the performance differences amongst chemical modifiers studied were much more pronounced. With the use of regular modifiers (Ir, Pd+Mg), pyrolysis and atomization temperatures for bismuth were 900-1000 and 2500 8C, respectively.…”
Section: Bimentioning
confidence: 96%
See 1 more Smart Citation
“…For the determination of bismuth in urine [51], the performance differences amongst chemical modifiers studied were much more pronounced. With the use of regular modifiers (Ir, Pd+Mg), pyrolysis and atomization temperatures for bismuth were 900-1000 and 2500 8C, respectively.…”
Section: Bimentioning
confidence: 96%
“…Elimination of matrix interferences (pyrolysis temperature for bismuth was 900 8C) allowed determination of bismuth in 1+1 diluted urine samples with calibration using aqueous standard solutions. A very low optimum atomization temperature (1400 8C) resulted in a rather long graphite tube lifetime (more than 500 determinations) [51].…”
Section: Bimentioning
confidence: 99%
“…The use of bismuth and its compounds is increasing, even though this element is known to be toxic for humans, animals and plants. [3][4][5] Although intestinal absorption of bismuth is limited in humans, because of its low solubility and its propensity to form insoluble oxychloride salts, absorption is certain to occur, and this produces measurable concentrations in body fluids and tissues. 6 As the use of bismuth in medicine increases, it has spread in the environment and the chance of exposure of organisms to bismuth has increased and a number of toxic effects in humans have been attributed to bismuth compounds.…”
Section: Introductionmentioning
confidence: 99%
“…The diluent was selected as described by Pinto et al 24 in human serum and based on the results obtained for Bi, Cr and Al determinations in human serum samples. [27][28][29] Multivariate optimization…”
Section: Choice Of Diluents and Modiersmentioning
confidence: 99%