2016
DOI: 10.1021/acs.jafc.6b04028
|View full text |Cite
|
Sign up to set email alerts
|

Direct Determination of Contaminants and Major and Minor Nutrients in Solid Fertilizers Using Laser-Induced Breakdown Spectroscopy (LIBS)

Abstract: Contaminants (Cd, Cr, and Pb) as well as minor (B, Cu, Mn, Na, and Zn) and major (Ca and Mg) elements were directly determined in solid fertilizer samples using laser-induced breakdown spectroscopy (LIBS). Factorial designs were used to define the most appropriate LIBS parameters and pellet pressure on solid fertilizers. Emission lines for all of the analytes were collected and employed 12 signal normalization modes. The best results were obtained using a laser energy of 75 mJ, a spot size of 50 μm, a pressure… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
24
0
3

Year Published

2017
2017
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 49 publications
(27 citation statements)
references
References 29 publications
0
24
0
3
Order By: Relevance
“…[80][81][82][83][84] Em trabalho proposto por Castro e Pereira-Filho, 43 a LIBS foi usada para análise direta de ligas metálicas, e as condições instrumentais (energia do pulso do laser, tempo de atraso e área do pulso) foram otimizadas utilizando planejamento do tipo Doehlert. No trabalho proposto por Andrade e Pereira-Filho, 85 a LIBS foi empregada para análise direta de fertilizantes. As variáveis instrumentais foram avaliadas com o uso de planejamento fatorial fracionário 2 4-1 .…”
Section: Libs E Quimiometriaunclassified
“…[80][81][82][83][84] Em trabalho proposto por Castro e Pereira-Filho, 43 a LIBS foi usada para análise direta de ligas metálicas, e as condições instrumentais (energia do pulso do laser, tempo de atraso e área do pulso) foram otimizadas utilizando planejamento do tipo Doehlert. No trabalho proposto por Andrade e Pereira-Filho, 85 a LIBS foi empregada para análise direta de fertilizantes. As variáveis instrumentais foram avaliadas com o uso de planejamento fatorial fracionário 2 4-1 .…”
Section: Libs E Quimiometriaunclassified
“…Multivariate analysis methods can take full advantage of LIBS spectral information and improve the accuracy of quantitative analyses. Multivariate calibration methods of LIBS quantitative analyses often involve PLS, multiple linear regression (MLR), ANN, SVM, or RF …”
Section: Quantitative Analysismentioning
confidence: 99%
“…The most common calibration curve is univariate, and its regression model is established using the intensity of a single feature line and the corresponding concentration of the element being tested. Andrade and Pereira Filho used LIBS to directly determine contaminants (Cd, Cr, and Pb) as well as major (Ca and Mg) and minor nutrients (B, Cu, Mn, Na, and Zn) in solid fertilizers; emission lines for all of the analytes were collected and used in 12 signal normalization modes. Good correlation was obtained between the predicted values and reference values.…”
Section: Quantitative Analysismentioning
confidence: 99%
“…Reference material with certified values concentration for masses in this range or lower are not commercially available. 38,44,45 Direct solid analysis also presents difficulties, such as the data reproducibility related to the ablation process, formation of the plasma, microheterogeneity and matrix effects, which in some cases can be minimized applying several types of normalizations or standardization on the raw data. 46 In the present study, a simple and fast method for the direct analysis of powdered samples of dietary supplements by LIBS to determine Ca, Mg and K was applied and discussed.…”
Section: Introductionmentioning
confidence: 99%