1980
DOI: 10.1016/s0021-9673(00)86382-7
|View full text |Cite
|
Sign up to set email alerts
|

Direct determination of organic compounds in water using steam-solid chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
4
0

Year Published

1982
1982
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(4 citation statements)
references
References 15 publications
0
4
0
Order By: Relevance
“…[1] Unfortunately, this VOC was detected in groundwater near a paint factory [4] and a petrochemical plant. [5] On account of the health issues mentioned above, the separation of IPB from water is crucial. Membrane separation technologies have many advantages over conventional separation processes, for example, they are energy-efficient, environmentally friendly, have a low capital cost, perform well in the separation, and operate in contentious mode.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…[1] Unfortunately, this VOC was detected in groundwater near a paint factory [4] and a petrochemical plant. [5] On account of the health issues mentioned above, the separation of IPB from water is crucial. Membrane separation technologies have many advantages over conventional separation processes, for example, they are energy-efficient, environmentally friendly, have a low capital cost, perform well in the separation, and operate in contentious mode.…”
Section: Introductionmentioning
confidence: 99%
“…[ 1 ] Unfortunately, this VOC was detected in groundwater near a paint factory [ 4 ] and a petrochemical plant. [ 5 ]…”
Section: Introductionmentioning
confidence: 99%
“…High levels of cumene have been found in groundwater near industrial sites and in industrial effluents. Concentrations of 360 [ 9 ] and 1581 μg/L [ 10 ] have been reported in groundwater near underground storage tanks, as high as 700 μg/L near outboard motor operations [ 11 ], and up to 54 μg/L near coal gasification facilities [ 12 ]. Cumene has been detected at lower levels (usually less than 5 μg/L) in groundwater not adjacent to a known industrial or a contaminated site [ 4 , 13 ].…”
Section: Introductionmentioning
confidence: 99%
“…Progress in gas chromatography (GC) makes it an excellent technique for near real-time monitoring of VOCs from air and water since the analytes are separated prior to their detection, allowing a flexible qualitative and quantitative analysis of these complex mixtures. Since the VOCs have a low concentration in air and water, direct injection of large volumes of sample in GC , causes excessive band broadening with losses of chromatographic resolution. Moreover, a large amount of water or air injected in the chromatographic column degrades the stationary phase.…”
mentioning
confidence: 99%