2009
DOI: 10.1016/j.orggeochem.2008.09.012
|View full text |Cite
|
Sign up to set email alerts
|

Direct Fourier transform mass spectral analysis of natural waters with low dissolved organic matter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
52
0
1

Year Published

2009
2009
2022
2022

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 51 publications
(54 citation statements)
references
References 35 publications
1
52
0
1
Order By: Relevance
“…Recently, electrospray ionization (ESI) coupled to Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), has emerged as a very promising technique in the characterization of DOM from different water environments (Stenson et al, 2003;Hertkorn et al, 2008;Kim et al, 2006;Sleighter et al, 2009) as well as the biological and photolytic transformation of DOM (Kim et al, 2006;Kujawinski et al, 2002;Kujawinski et al, 2004;Hertkorn et al, 2007;Gonsior et al, 2009). The ultrahigh resolution and mass accuracy of FT-ICR MS provides molecular masses accurate to within 1 ppm, which often enables the determination of molecular formulas by mass measurement alone (Stenson et al, 2003;Kim et al, 2006).…”
Section: Introductionmentioning
confidence: 99%
“…Recently, electrospray ionization (ESI) coupled to Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), has emerged as a very promising technique in the characterization of DOM from different water environments (Stenson et al, 2003;Hertkorn et al, 2008;Kim et al, 2006;Sleighter et al, 2009) as well as the biological and photolytic transformation of DOM (Kim et al, 2006;Kujawinski et al, 2002;Kujawinski et al, 2004;Hertkorn et al, 2007;Gonsior et al, 2009). The ultrahigh resolution and mass accuracy of FT-ICR MS provides molecular masses accurate to within 1 ppm, which often enables the determination of molecular formulas by mass measurement alone (Stenson et al, 2003;Kim et al, 2006).…”
Section: Introductionmentioning
confidence: 99%
“…The ultrahigh resolution and mass accuracy of FT-ICR MS provides molecular masses accurate to within 1 ppm, which often enables the determination of elemental formulae from the mass measurement alone (Kim et al, 2006). Numerous investigators have used ESI FT-ICR MS to characterize DOM collected from rainwater (Altieri et al, 2009), atmospheric aerosols (Wozniak et al, 2008), glaciers (Grannas et al, 2006;Bhatia et al, in press), freshwater (Kim et al, 2006;Sleighter et al, 2009), the coastal ocean Kujawinski et al, 2009), the open ocean (Dittmar and Koch, 2006;Koch et al, 2008), sediment porewater (Schmidt et al, 2009), and culture studies (Kujawinski et al, 2004;Rossello-Mora et al, 2008).…”
Section: Introductionmentioning
confidence: 99%
“…As shown in the Supporting Information (page S6), all CHO and CHON 5 S 2 components are extracted from the database (using autofilter) into separate spreadsheets. In an additional column, R SAMPLE is the measured 13 C/ 12 C isotope ratio received by the quotient of the intensity of the C c H h O o N 5 S 2 component (assumed 13 C isotope peak, here set as 13 C 1 12 C x−1 H y O z ) and the intensity of the corresponding C c+6 H h−3 O o+4 N 0 S 0 component (here set as 12 C x H y O z ). The value 0.0112372 is the 13 C/ 12 C isotope ratio of the international CaCO 3 standard.…”
mentioning
confidence: 99%