2015
DOI: 10.1016/j.powtec.2015.08.033
|View full text |Cite
|
Sign up to set email alerts
|

Direct fractionation of spray-dried polymeric microparticles by inertial impaction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
12
0
2

Year Published

2017
2017
2021
2021

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 25 publications
(14 citation statements)
references
References 36 publications
0
12
0
2
Order By: Relevance
“…Generally, a higher solid concentration results in a lower feed rate (Beck-Broichsitter et al 2015b; Schmid 2011). A lower relative spray rate intensity reduces the feed rate almost linearly (Beck-Broichsitter et al 2015b). Figure 4B shows a linear correlation between the inlet and the outlet temperature for DCM solution in the Nano Spray Dryer B-90 (Büchi Labortechnik AG 2011).…”
Section: Influence Of Process Parameters On Powder Propertiesmentioning
confidence: 99%
See 1 more Smart Citation
“…Generally, a higher solid concentration results in a lower feed rate (Beck-Broichsitter et al 2015b; Schmid 2011). A lower relative spray rate intensity reduces the feed rate almost linearly (Beck-Broichsitter et al 2015b). Figure 4B shows a linear correlation between the inlet and the outlet temperature for DCM solution in the Nano Spray Dryer B-90 (Büchi Labortechnik AG 2011).…”
Section: Influence Of Process Parameters On Powder Propertiesmentioning
confidence: 99%
“…C Feed rate as a function of the spray mesh size: (black bars) pure DCM (Büchi Labortechnik 2011) and (white bars) 5% (w/v) PLGA solution with sildenafil (10% of polymer mass) in acetone (Beck-Broichsitter et al 2015b) For pure DCM, the feed rates are in the ranges of 18, 32 and 107 g/h for a 4.0, 5.5, and 7.0 µm spray mesh, respectively (Büchi Labortechnik AG 2010). A significant increase in the flow rate from 18 to 128 g/h with a spray mesh size of 4.0 and 7.0 μm was also observed with a 5% (w/v) PLGA solution in acetone (Beck-Broichsitter et al 2015b). Figure 5 shows some SEM images of representative nano spray dried PLA/PLGA particles.…”
Section: Influence Of Process Parameters On Powder Propertiesmentioning
confidence: 99%
“…Similarly, the outlet temperature increases with a smaller feed rate. 50,70 A drier powder is obtained at a higher inlet temperature. 71 Typical residual moisture contents of nano spraydried mannitol are below 0.5% and 2% to 5% for trehalose.…”
Section: Influence Of Process Parameters On Powder Propertiesmentioning
confidence: 99%
“…O sistemade LEE et al, 2011) . Nesse momento, gotículas de tamanho uniforme são depositadas sobre a membrana, e o movimento vibracional promove a aspersão das gotículas pelo orifício da membrana para dentro da câmara de secagem (BROICHSITTER; STREHLOW;KISSEL, 2015). No sistema de aquecimento, uma espuma de metal porosa e compacta conduz o gás quente para dentro da câmara de secagem num fluxo laminar e numa taxa de aquecimento suave.…”
unclassified
“…Isso ocorre devido ao fato das micropartículas secas no pulverizador da série Nano, não passarem por um fracionamento, quanto ao seu tamanho, durante a etapa de recuperação no coletor eletrostático. Embora não ocorra esse fracionamento, esse pulverizador pode oferecer um índice de recuperação de partículas maior comparado a outros pulverizadores, uma vez que produtos farmacêuticos são caros e testados em baixa quantidade (BROICHSITTER; STREHLOW;KISSEL, 2015). Os pulverizadores da série Mini Spray Dryer possuem um sistema de coleta diferente, composto por um ciclone, o qual remove partículas menores, aumentando R50 b -40% c ) para 70% (Q95 a R50 b -70% c ) com relação à massa de quitosana.…”
unclassified