2017
DOI: 10.1016/j.bios.2017.07.017
|View full text |Cite
|
Sign up to set email alerts
|

Direct immune-detection of cortisol by chemiresistor graphene oxide sensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
32
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 70 publications
(32 citation statements)
references
References 19 publications
0
32
0
Order By: Relevance
“…In these studies, the detection of the cortisol is achieved by the inhibition of the surface for redox reaction [19][20][21][22][23] . In addition, chemiresistor-immunosensors followed a similar strategy 24,25 . Among the electrochemical sensors, the ones using graphene and its derivatives 26…”
mentioning
confidence: 99%
“…In these studies, the detection of the cortisol is achieved by the inhibition of the surface for redox reaction [19][20][21][22][23] . In addition, chemiresistor-immunosensors followed a similar strategy 24,25 . Among the electrochemical sensors, the ones using graphene and its derivatives 26…”
mentioning
confidence: 99%
“…Molecularly imprinted polymers (MIPs) are recently studied as alternatives and used in assays to overcome the economic downsides of antibody-based assays [ 43 ]. Similarly, bio- or chemiluminescent assays may serve as alternatives [ [44] , [45] , [46] , [47] , [48] , [49] ].…”
Section: Assaysmentioning
confidence: 99%
“…In addition to classical immunoassays, immunological methods and electrochemical analysis are often combined in stress marker analyses [ [50] , [51] , [52] , [53] , [54] , [55] ]. Bio- and immunosensors are widespread thanks to their versatility, easy use, sensitivity, and short analysis time [ 45 , 46 , [50] , [51] , [52] , [53] , [54] , [55] , [56] ]. Furthermore, due to their possibility of miniaturization, they offer an excellent opportunity for developing point of care (POC) devices.…”
Section: Assaysmentioning
confidence: 99%
See 1 more Smart Citation
“…Recently, electrochemical sensors [25][26][27], surface plasmon resonance (SPR) sensors [28] and impedimetric biosensors [29] have been introduced into cortisol investigation and achieved great progress, even though these technologies require mediators, complex electrode fabrication, indirect cortisol measurement, high-voltage investigation, or modification of the analyte itself. Generally, extensive efforts regarding high-sensitivity cortisol estimation via electrochemical immunosensors have been published and excellent detection limits of 1 pM to 1 µM have been obtained by the sensors [18,25,26,[30][31][32]. In these studies, different dimensions of nanomaterials have been utilized in the electrochemical sensors to improve the biocompatible, electroactive and biologically functional immobilization matrices.…”
Section: Introductionmentioning
confidence: 99%