2021
DOI: 10.1016/j.jpowsour.2021.230292
|View full text |Cite
|
Sign up to set email alerts
|

Direct measurement of current distribution in lithium-ion cells by magnetic field imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
22
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 24 publications
(22 citation statements)
references
References 24 publications
0
22
0
Order By: Relevance
“…Thus, the current distribution can be visualized by measuring the battery-induced magnetic field, and the batteries with bidirectional or unidirectional tabs coincide uniformly with the simulation results. [49] Magnetic sensor analysis of the magnetic field and current distribution can be applied to detect defects in a pack containing several batteries, beyond the simple detection of imbalances and defects in a single battery. For instance, Wu et al visualized the magnetic fields of a battery pack and detected an imbalance in the capacity across the batteries in the pack (Figure 12c).…”
Section: Magnetic Field Imaging (Mfi) Of Li-ion Pouch Cellsmentioning
confidence: 99%
See 3 more Smart Citations
“…Thus, the current distribution can be visualized by measuring the battery-induced magnetic field, and the batteries with bidirectional or unidirectional tabs coincide uniformly with the simulation results. [49] Magnetic sensor analysis of the magnetic field and current distribution can be applied to detect defects in a pack containing several batteries, beyond the simple detection of imbalances and defects in a single battery. For instance, Wu et al visualized the magnetic fields of a battery pack and detected an imbalance in the capacity across the batteries in the pack (Figure 12c).…”
Section: Magnetic Field Imaging (Mfi) Of Li-ion Pouch Cellsmentioning
confidence: 99%
“…This poses substantial limitations on data extraction concerning charge transfer in the direction of the battery depth. [49] Therefore, it is forecasted that improvements in 3D imaging analysis and the incorporation of charge Figure 12. a) i) Scheme of the experimental arrangement for measuring magnetic field.…”
Section: Magnetic Field Imaging (Mfi) Of Li-ion Pouch Cellsmentioning
confidence: 99%
See 2 more Smart Citations
“…the Magnetoresistive sensor is manufactured by thin-film technology, which allows them to be highly integrated. Brauchle et al reported an anisotropic magnetoresistive (AMR) sensor to map the magnetic field and achieve the detection of 227 mA⋅cm −2 current density [ 14 ]. The TMR sensor also plays an important role in battery magnetic imaging.…”
Section: Introductionmentioning